1/4″x11 1/2″ Cooley Suction Tube – vascula round perf end
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-42316
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-42316AISI 420 Martensitic

11 1/2″ Cooley Suction Tube Vascular Round Perf End

4.9 / 5.0•18 Verified OR Evaluations
$169.00$189.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (11% OFF)
  • 11 1/2″ Cooley Suction Tube Vascular Round Perf End designed with a round configuration for fluid management during cardiovascular procedures.
  • Round perforated end provides a defined suction profile for vascular applications.
  • Round design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a suction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 11 1/2″ Cooley Suction Tube Vascular Round Perf End is a specialized cardiovascular instrument designed for fluid management during vascular and cardiovascular procedures. Its round perforated end provides a distinct working orientation that can assist with positioning the suction end within the operative field.

With an overall length of 11 1/2 inches and a dedicated suction profile, this suction tube provides a defined aspiration capability for cardiovascular applications. The design allows the working end to approach the surgical site effectively, supporting controlled manual manipulation during procedures.

Key Features

  • 11 1/2-inch overall length for controlled manual handling.
  • Round perforated end provides a defined suction profile.
  • Suction configuration for specialized working orientation.
  • Designed for fluid management during vascular procedures.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports positioning of the suction end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Suction Tube
Overall Length11 1/2″
Working End / Blade / JawRound perforated end
ConfigurationRound
Primary FunctionFluid Management
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 11 1/2″ Cooley Suction Tube Vascular Round Perf End combines a 11 1/2-inch overall length with a round perforated end.
Its defined suction profile is intended for fluid management in cardiovascular applications.

Design & Function

The Cooley Suction Tube features a round working configuration designed to provide a specialized orientation during fluid aspiration. The round perforated end can assist in positioning the suction end according to the requirements of the operative field.

The round perforated end provides a defined suction profile, while the 11 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a suction instrument.

Surgical Applications

The 11 1/2″ Cooley Suction Tube Vascular Round Perf End may be used for cardiovascular and vascular surgery applications involving fluid aspiration. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Suction Tube before use, paying particular attention to the working end and perforations. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Suction Tube appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cooley Suction Tube?
The overall length is 11 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features round perforated end.

3. Is this Cooley Suction Tube curved or straight?
It features a round configuration.

4. What is a Cooley Suction Tube used for?
It is designed for controlled fluid management in cardiovascular applications.

5. What clinical advantage does the round perforated end provide?
The round perforated end provides a specialized working orientation for positioning the suction end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular applications where a round suction instrument is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Cooley Suction Tube be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.