10 1/2″ DeBakey Aortic Aneurysm Clamp 8.5cm 1×2 Teeth
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/2″ DeBakey Aortic Aneurysm Clamp designed with an atraumatic configuration for secure vessel occlusion.
- 8.5 cm jaw length provides a defined clamping profile for cardiovascular procedures.
- Atraumatic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and aortic surgery applications requiring an atraumatic clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/2″ DeBakey Aortic Aneurysm Clamp is a specialized cardiovascular instrument designed for secure occlusion during aortic aneurysm repair. Its 8.5 cm jaw with 1×2 teeth provides a firm grip while maintaining atraumatic control, ensuring safe vessel handling in complex procedures.
With an overall length of 10 1/2 inches and an 8.5 cm jaw length, this clamp provides a defined clamping profile for cardiovascular applications. The atraumatic design allows the working end to approach the vessel from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/2-inch overall length for extended reach.
- 8.5 cm jaw length provides effective occlusion.
- 1×2 teeth configuration for secure vessel engagement.
- Designed for atraumatic vessel handling.
- Suitable for cardiovascular applications.
- Supports positioning of the working end within the operative field.
- Specialized DeBakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | DeBakey Aortic Aneurysm Clamp |
| Overall Length | 10 1/2″ |
| Working End / Blade / Jaw | 8.5 cm or 1×2 teeth |
| Configuration | Atraumatic |
| Primary Function | Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular |
The 10 1/2″ DeBakey Aortic Aneurysm Clamp combines a 10 1/2-inch overall length with an 8.5 cm jaw length and 1×2 teeth configuration.
Its defined working profile is intended for vessel occlusion in cardiovascular applications.
Design & Function
The DeBakey Aortic Aneurysm Clamp features an atraumatic working configuration designed to provide a specialized orientation during aortic aneurysm repair. The jaw design can assist in positioning the working end according to the requirements of the operative field.
The 8.5 cm jaw length provides a defined clamping profile, while the 10 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an atraumatic clamp.
Surgical Applications
The 10 1/2″ DeBakey Aortic Aneurysm Clamp may be used for cardiovascular and aortic surgery applications involving secure vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the DeBakey Aortic Aneurysm Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Aortic Aneurysm Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 10 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features 8.5 cm jaw length with 1×2 teeth.
3. Is this Clamp curved or straight?
It features an atraumatic configuration.
4. What is a DeBakey Aortic Aneurysm Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.
5. What clinical advantage does the atraumatic design provide?
The atraumatic design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and aortic surgery applications where an atraumatic clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the DeBakey Aortic Aneurysm Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.