10 1/2″ Grant Abdominal Aorta Clamp
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/2″ Grant Abdominal Aorta Clamp designed with a curved configuration for secure vessel occlusion.
- Robust clamping profile provides a defined occlusion capability for cardiovascular procedures.
- Ergonomic design supports a specialized working orientation within the operative field.
- Suitable for vascular and cardiac surgery applications requiring a robust clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/2″ Grant Abdominal Aorta Clamp is a specialized cardiovascular instrument designed for secure, atraumatic occlusion of the abdominal aorta in cardiovascular and vascular procedures. Its robust design and ergonomic handles allow precise control in deep abdominal surgical fields.
With an overall length of 10 1/2 inches and a strong clamping profile, this clamp provides a defined occlusion capability for vascular applications. The ergonomic design allows the working end to approach the abdominal aorta from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/2-inch overall length for controlled manual handling.
- Robust clamping profile provides a defined occlusion capability.
- Ergonomic design for specialized working orientation.
- Designed for secure vessel control during major surgeries.
- Suitable for vascular, cardiac, and reconstructive applications.
- Supports positioning of the working end within the operative field.
- Specialized Grant pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Grant Abdominal Aorta Clamp |
| Overall Length | 10 1/2″ |
| Working End / Blade / Jaw | Robust clamping profile |
| Configuration | Curved |
| Primary Function | Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 10 1/2″ Grant Abdominal Aorta Clamp combines a 10 1/2-inch overall length with a robust clamping profile and curved configuration.
Its defined working profile is intended for secure vessel control during major surgeries in cardiovascular applications.
Design & Function
The Grant Abdominal Aorta Clamp features a curved working configuration designed to provide a specialized orientation during vessel occlusion. The robust clamping profile can assist in positioning the working end according to the requirements of the operative field.
The clamping profile provides a defined occlusion capability, while the 10 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a robust clamp.
Surgical Applications
The 10 1/2″ Grant Abdominal Aorta Clamp may be used for cardiovascular and vascular surgery applications involving secure occlusion of the abdominal aorta. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Grant Abdominal Aorta Clamp before use, paying particular attention to the working end and jaw alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Grant Abdominal Aorta Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 10 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features robust clamping profile.
3. Is this Clamp curved or straight?
It features a curved configuration.
4. What is a Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.
5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a robust clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.