10 1/4″ Rienhoff Swan-Neck Clamp Double Curved
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/4″ Rienhoff Swan-Neck Clamp Double Curved designed with a double curved configuration for effective clamping of vessels and tissue.
- Double curved jaws provide a defined clamping profile for neurosurgical procedures.
- Double curved design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and thoracic applications requiring a double curved clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/4″ Rienhoff Swan-Neck Clamp Double Curved is a specialized neurosurgical instrument designed for effective clamping of vessels or tissue in deep and restricted surgical fields. Its unique swan-neck profile combined with double-curved jaws allows for precise placement and optimal clamping during procedures.
With an overall length of 10 1/4 inches and a robust design, this clamp provides a defined clamping profile for neurosurgical applications. The double-curved configuration allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during surgeries.
Key Features
- 10 1/4-inch overall length for effective handling in deep surgical fields.
- Double curved jaws provide a precise clamping profile.
- Swan-neck design for enhanced access to restricted areas.
- Designed for effective clamping of vessels and tissue.
- Suitable for neurosurgical, thoracic, and cardiovascular applications.
- Supports positioning of the working end within the operative field.
- Strong ratchet locking mechanism for secure clamping.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Rienhoff Swan-Neck Clamp |
| Overall Length | 10 1/4″ |
| Working End / Blade / Jaw | Double Curved Jaws |
| Configuration | Double Curved |
| Primary Function | Clamping of Vessels and Tissue |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Thoracic / Cardiovascular |
The 10 1/4″ Rienhoff Swan-Neck Clamp Double Curved combines a 10 1/4-inch overall length with double curved jaws.
Its defined clamping profile is intended for effective clamping of vessels and tissue in neurosurgical applications.
Design & Function
The Rienhoff Swan-Neck Clamp features a double curved working configuration designed to provide specialized orientation during surgical procedures. The double-curved jaw design can assist in positioning the working end according to the requirements of the operative field.
The double curved jaws provide a defined clamping profile, while the 10 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a specialized clamping instrument.
Surgical Applications
The 10 1/4″ Rienhoff Swan-Neck Clamp Double Curved may be used for neurosurgical and thoracic applications involving effective clamping of vessels and tissue. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Rienhoff Swan-Neck Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Rienhoff Swan-Neck Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 10 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features double curved jaws.
3. Is this Clamp curved or straight?
It features a double curved configuration.
4. What is a Rienhoff Swan-Neck Clamp used for?
It is designed for controlled clamping of vessels and tissue in neurosurgical applications.
5. What clinical advantage does the double curved design provide?
The double curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and thoracic applications where a double curved clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.