
10 1/4″ Debakey Semb Ligature Carrier
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/4″ Debakey Semb Ligature Carrier designed with an ergonomic configuration for accurate ligature placement.
- Slender working end provides a defined grasping profile for cardiovascular procedures.
- Ergonomic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and general surgery applications requiring an ergonomic Ligature Carrier.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/4″ Debakey Semb Ligature Carrier is a specialized cardiovascular instrument designed for precise placement and manipulation of ligatures in deep or confined surgical fields. Its slender profile and ergonomic design allow controlled handling while minimizing tissue disruption.
With an overall length of 10 1/4 inches and a slender working end, this Ligature Carrier provides a defined grasping profile for cardiovascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/4-inch overall length for controlled manual handling.
- Slender working end provides a defined grasping profile.
- Ergonomic design for specialized working orientation.
- Designed for accurate ligature placement.
- Suitable for cardiovascular and general surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Debakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Debakey Semb Ligature Carrier |
| Overall Length | 10 1/4″ |
| Working End / Blade / Jaw | Slender working end |
| Configuration | Ergonomic |
| Primary Function | Ligature Placement |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / General Surgery |
The 10 1/4″ Debakey Semb Ligature Carrier combines a 10 1/4-inch overall length with a slender working end and ergonomic design.
Its defined working profile is intended for accurate ligature placement in cardiovascular applications.
Design & Function
The Debakey Semb Ligature Carrier features an ergonomic working configuration designed to provide a specialized orientation during ligature placement. The slender working end design can assist in positioning the working end according to the requirements of the operative field.
The slender working end provides a defined grasping profile, while the 10 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an ergonomic instrument type.
Surgical Applications
The 10 1/4″ Debakey Semb Ligature Carrier may be used for cardiovascular and general surgery applications involving precise ligature placement. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Debakey Semb Ligature Carrier before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Semb Ligature Carrier appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Ligature Carrier?
The overall length is 10 1/4 inches.
2. What is the working end design of the instrument?
It features a slender working end.
3. Is this Ligature Carrier curved or straight?
It features an ergonomic configuration.
4. What is a Ligature Carrier used for?
It is designed for controlled ligature placement in cardiovascular applications.
5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and general surgery applications where a slender Ligature Carrier is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Ligature Carrier be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
