10 1/4″ Landolt-Reulen Hook 1.7mm Blunt
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/4″ Landolt-Reulen Hook designed with a blunt configuration for safe manipulation of delicate neural structures.
- 1.7 mm blunt tip provides a defined engagement profile for neurosurgical procedures.
- Blunt design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and microsurgical applications requiring a blunt instrument type.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/4″ Landolt-Reulen Hook is a specialized neurosurgical instrument designed for safe manipulation of delicate neural and vascular structures. Its 1.7mm blunt tip allows atraumatic engagement, reducing the risk of tissue injury during neurosurgical and microsurgical procedures.
With an overall length of 10 1/4 inches and a 1.7mm blunt tip, this hook provides exceptional reach and balance for deep operative fields. The design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/4-inch overall length for exceptional reach and balance.
- 1.7 mm blunt tip provides a defined engagement profile.
- Blunt configuration for atraumatic tissue handling.
- Designed for safe manipulation of delicate neural and vascular structures.
- Suitable for neurosurgical and microsurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Landolt-Reulen pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Landolt-Reulen Hook |
| Overall Length | 10 1/4″ |
| Working End / Blade / Jaw | 1.7 mm blunt tip |
| Configuration | Blunt |
| Primary Function | Safe Manipulation of Neural Structures |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Microsurgery |
The 10 1/4″ Landolt-Reulen Hook combines a 10 1/4-inch overall length with a 1.7 mm blunt tip and blunt configuration.
Its defined working profile is intended for safe manipulation of delicate neural and vascular structures in neurosurgical applications.
Design & Function
The Landolt-Reulen Hook features a blunt working configuration designed to provide a specialized orientation during microsurgical procedures. The blunt tip can assist in positioning the working end according to the requirements of the operative field.
The 1.7 mm blunt tip provides a defined engagement profile, while the 10 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a blunt instrument type.
Surgical Applications
The 10 1/4″ Landolt-Reulen Hook may be used for neurosurgical and microsurgical applications involving safe manipulation of delicate neural and vascular structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Landolt-Reulen Hook before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Landolt-Reulen Hook appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Landolt-Reulen Hook?
The overall length is 10 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 1.7 mm blunt tip.
3. Is this Landolt-Reulen Hook curved or straight?
It features a blunt configuration.
4. What is a Landolt-Reulen Hook used for?
It is designed for controlled safe manipulation of neural structures in neurosurgical applications.
5. What clinical advantage does the blunt tip provide?
The blunt tip provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and microsurgical applications where a blunt instrument type is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Landolt-Reulen Hook be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.