
10 1/4″ Satinsky Vena Cava Clamp Cross-Serrated Jaws
Direct Manufacturer Pricing • Tax Exclusive
- 10 1/4″ Satinsky Vena Cava Clamp designed with an angled configuration for partial or complete occlusion of large vessels.
- Cross-serrated jaws provide a defined clamping profile for cardiovascular procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and thoracic surgery applications requiring an angled clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10 1/4″ Satinsky Vena Cava Clamp is a specialized cardiovascular instrument designed for partial or complete occlusion of large vessels such as the vena cava. Its cross-serrated jaws provide a distinct working orientation that can assist with positioning the clamp within the operative field.
With an overall length of 10 1/4 inches and a secure gripping mechanism, this clamp provides a defined clamping profile for cardiovascular applications. The angled design allows the working end to approach vessels without completely interrupting blood flow, supporting controlled manual manipulation during procedures.
Key Features
- 10 1/4-inch overall length for controlled manual handling.
- Cross-serrated jaws provide a defined clamping profile.
- Angled configuration for specialized working orientation.
- Designed for partial or complete occlusion of large vessels.
- Suitable for cardiovascular and thoracic surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Satinsky pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Satinsky Vena Cava Clamp |
| Overall Length | 10 1/4″ |
| Working End / Blade / Jaw | Cross-serrated jaws |
| Configuration | Angled |
| Primary Function | Partial or Complete Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Thoracic Surgery |
The 10 1/4″ Satinsky Vena Cava Clamp combines a 10 1/4-inch overall length with cross-serrated jaws and an angled configuration.
Its defined clamping profile is intended for partial or complete occlusion in cardiovascular applications.
Design & Function
The Satinsky Vena Cava Clamp features an angled working configuration designed to provide a specialized orientation during vessel occlusion. The cross-serrated jaw design can assist in positioning the clamp according to the requirements of the operative field.
The cross-serrated jaws provide a defined clamping profile, while the 10 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled clamp.
Surgical Applications
The 10 1/4″ Satinsky Vena Cava Clamp may be used for cardiovascular and thoracic surgery applications involving the occlusion of large vessels. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Satinsky Vena Cava Clamp before use, paying particular attention to the working end, jaw alignment, and gripping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Satinsky Vena Cava Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Satinsky Vena Cava Clamp?
The overall length is 10 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features cross-serrated jaws.
3. Is this Satinsky Vena Cava Clamp curved or straight?
It features an angled configuration.
4. What is a Satinsky Vena Cava Clamp used for?
It is designed for controlled partial or complete occlusion in cardiovascular applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and thoracic surgery applications where an angled clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Satinsky Vena Cava Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
