10 1 4″ Cooley Aortic Aneurysm Clamp Curved Jaws
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-84805
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ClampsSKU: SP-84805AISI 420 Martensitic

10 1/4″ Cooley Aortic Aneurysm Clamp Curved Jaws

4.9 / 5.0•18 Verified OR Evaluations
$85.00$110.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $25.00 (23% OFF)

The 10 1/4″ Cooley Aortic Aneurysm Clamp with Curved Jaws is a specialized cardiovascular surgical instrument designed for controlled clamping of appropriate vascular structures. Its curved jaw configuration supports access and positioning during selected aortic and vascular procedures.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 10 1/4″ Cooley Aortic Aneurysm Clamp with Curved Jaws is a specialized vascular surgical instrument intended for selected cardiovascular procedures involving the aorta and other appropriate blood vessels. Designed in the Cooley pattern, this clamp provides a controlled mechanism for engaging vascular tissue when temporary clamping is required as part of a surgeon's planned technique.

With an overall length of 10 1/4 inches, this instrument offers a practical size for cardiovascular surgical settings where precise instrument placement and access are important. Its curved jaw configuration can help accommodate anatomical contours and surgical approaches in which straight jaws may be less suitable. The exact clamping function, jaw profile, and degree of vascular occlusion should be confirmed through the manufacturer's specifications.

Curved Jaw Design and Function

The curved jaws distinguish this Cooley aortic aneurysm clamp from straight-jaw vascular clamps. This configuration may facilitate positioning around or alongside the intended vascular structure, depending on the operative approach and the specific jaw geometry.

The handle and clamping mechanism allow the user to apply controlled closure according to the instrument's design. Jaw alignment, surface finish, and closure characteristics are important considerations for vascular instruments because they influence tissue engagement and clamping performance.

The product title does not specify the jaw length, curvature angle, serration pattern, or partial- versus complete-occlusion design. These details should be verified with the manufacturer rather than assumed. Selection should be based on the vessel, surgical technique, and intended clamping requirements.

Applications in Cardiovascular Surgery

Cooley-pattern vascular clamps are associated with cardiovascular and vascular surgical instrumentation. Depending on the specific model and its approved intended use, an aortic aneurysm clamp may be selected for procedures involving aortic exposure, vascular reconstruction, or other operations requiring temporary vascular control.

Curved-jaw designs may be useful when the surgical approach calls for a curved instrument profile. However, not every vascular clamp is appropriate for every vessel or procedure. The surgeon must confirm that the instrument's design and clamping characteristics are suitable for the intended application.

For hospitals, cardiovascular surgical centers, and medical instrument distributors, accurate identification of the clamp pattern and jaw configuration helps ensure that the supplied instrument matches the surgical team's requirements.

Construction and Material Considerations

The product title identifies the Cooley pattern, curved jaws, and overall length but does not specify the manufacturing material or surface finish. The exact material grade, construction details, and corrosion-resistance characteristics should be confirmed with the supplier before being included in the product specifications.

A professional vascular clamp should have properly aligned jaws, smooth mechanical operation, and a reliable handle and joint assembly. The closure mechanism should function as intended, and the working surfaces should remain free of defects that could compromise instrument performance.

Before use, inspect the jaw alignment, gripping surfaces, joint, and locking mechanism. Any instrument showing corrosion, deformation, looseness, or irregular closure should be removed from service in accordance with the healthcare facility's procedures.

Cleaning, Sterilization, and Maintenance

If supplied as a reusable surgical instrument, the Cooley aortic aneurysm clamp must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions for use. Special attention should be given to the jaws, joint, and any locking components where biological material may accumulate.

After cleaning, check the instrument for residual soil, mechanical wear, jaw misalignment, and defects that could affect closure. Sterilization compatibility and processing parameters must be confirmed from the manufacturer's documentation. Do not assume that a particular sterilization cycle is suitable without verified instructions.

Routine inspection and appropriate reprocessing help maintain instrument condition and support its continued suitability for clinical use when reuse is approved by the manufacturer.

A Specialized Clamp for Vascular Instrument Sets

The 10 1/4″ Cooley Aortic Aneurysm Clamp with Curved Jaws provides a defined instrument pattern, jaw configuration, and overall length for cardiovascular surgical procurement. Its curved profile distinguishes it from straight vascular clamps and may support specific access requirements when appropriate for the procedure.

Before purchasing, verify the jaw dimensions, curvature, intended occlusion characteristics, material, locking mechanism, and approved reprocessing requirements. These details help healthcare professionals and procurement teams select the correct vascular instrument for the intended clinical application.

Key Features

  • Cooley-pattern aortic aneurysm clamp.

  • Curved jaw configuration for suitable vascular access.

  • Overall length of 10 1/4 inches.

  • Designed for selected cardiovascular and vascular surgical applications.

  • Intended for controlled clamping of appropriate vascular structures.

  • Curved profile distinguishes it from straight-jaw vascular clamps.

  • Jaw dimensions and occlusion characteristics should be confirmed with the manufacturer.

  • Inspect jaw alignment, joint movement, and closure before use.

  • Verify material grade and construction specifications with the supplier.

  • Follow manufacturer-approved cleaning and sterilization instructions.

  • Intended for use by trained healthcare professionals.

Product Specifications

SpecificationDetails
Product NameCooley Aortic Aneurysm Clamp
Instrument CategoryCardiovascular Surgical Instruments
PatternCooley
Overall Length10 1/4 inches
Jaw ConfigurationCurved
Instrument TypeAortic Aneurysm Clamp
Primary ApplicationSelected vascular and cardiovascular procedures
Jaw LengthNot specified
Occlusion TypeTo be confirmed with manufacturer
Locking MechanismTo be confirmed
MaterialTo be confirmed with manufacturer
Surface FinishTo be confirmed
Reusable StatusTo be confirmed with manufacturer
SterilizationFollow manufacturer instructions for use
Product Code / SKUTo be assigned

Frequently Asked Questions

1. What is a Cooley aortic aneurysm clamp used for?

A Cooley aortic aneurysm clamp is a specialized vascular instrument associated with procedures involving the aorta and other appropriate blood vessels. Its specific application depends on the model's design and intended clamping function.

2. What is the length of this Cooley aortic aneurysm clamp?

The specified overall length is 10 1/4 inches, providing a useful measurement for surgical instrument selection and procurement.

3. What is the benefit of curved jaws on an aortic clamp?

Curved jaws may help the surgeon position the instrument around or alongside a vascular structure when the operative approach requires a curved profile. Suitability depends on the anatomy and the specific clamp design.

4. Is this clamp suitable for cardiovascular surgery?

The instrument is categorized as a cardiovascular surgical clamp. Its suitability for a particular procedure must be established by confirming the manufacturer's intended use, jaw design, and clamping characteristics.

5. What material is used to manufacture the Cooley aortic aneurysm clamp?

The product title does not specify the exact material. Buyers should confirm the material grade, finish, and construction details with the manufacturer.

6. Is the Cooley aortic aneurysm clamp reusable?

Reusable status depends on the manufacturer's specifications. If the instrument is intended for reuse, it must be cleaned, inspected, and sterilized according to the validated instructions for use.

7. How should a curved aortic aneurysm clamp be maintained?

Inspect the jaws, joint, closure mechanism, and locking components before use. Follow the manufacturer's approved cleaning and sterilization procedures, and remove any damaged or malfunctioning instrument from service.

8. What should buyers check before purchasing a Cooley aortic aneurysm clamp?

Confirm the overall length, jaw curvature, jaw dimensions, intended occlusion function, material, locking mechanism, and reprocessing requirements to ensure the instrument meets the surgical team's needs.