10″ Satinsky Vena Cava Clamp 4.0cm Long, 9mm Deep Jaws
Direct Manufacturer Pricing • Tax Exclusive
The 10″ Satinsky Vena Cava Clamp features 4.0 cm long and 9 mm deep jaws for specialized cardiovascular and vascular surgical applications. Its 10-inch overall length and Satinsky pattern provide clear identification for professional surgical instrument procurement.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 10″ Satinsky Vena Cava Clamp with 4.0 cm long and 9 mm deep jaws is a specialized cardiovascular surgical instrument intended for controlled vascular clamping in appropriate surgical procedures. The Satinsky pattern is commonly associated with angled jaws designed to facilitate access to selected blood vessels when a particular clamping approach is required. The precise application of this model should be confirmed against the manufacturer's specifications.
With an overall length of 10 inches (25.4 cm), this vascular clamp provides an extended instrument profile for suitable operative settings. Its specified jaw dimensions help healthcare professionals and medical procurement teams distinguish it from other Satinsky clamps with different working-end sizes.
Jaw Design and Dimensions
This Satinsky Vena Cava Clamp features jaws measuring 4.0 cm (40 mm) in length and 9 mm in depth. These dimensions are important when selecting vascular instruments because the working-end size influences access and the area of tissue engaged during clamping.
The Satinsky design is recognized for its angled jaw profile, which can support selected vascular clamping techniques, including partial occlusion when appropriate for the instrument and procedure. The exact curvature, jaw surface, and closing characteristics of this specific model should be verified with the supplier before clinical use.
Cardiovascular and Vascular Surgical Applications
Satinsky clamps are used in selected cardiovascular and vascular procedures that require controlled engagement of blood vessels. Depending on the instrument's precise design, they may be appropriate for procedures involving the vena cava or other vascular structures.
The 4.0 cm jaw length and 9 mm depth provide useful reference measurements for comparing models and maintaining accurate instrument inventories. Final selection should consider vessel anatomy, the required degree of occlusion, the surgical approach, and the surgeon's established technique.
Because vascular tissue is sensitive to mechanical pressure, this clamp must be used only by qualified surgical professionals in accordance with its intended purpose. The product name and dimensions alone do not establish suitability for every vascular procedure.
Material and Construction
Vascular surgical clamps are commonly manufactured from medical-grade stainless steel because of its strength, corrosion resistance, and suitability for validated cleaning and sterilization procedures when designed for reuse. The exact material grade, finish, and construction of this specific instrument should be confirmed by the manufacturer.
Instrument performance depends on proper jaw alignment, reliable mechanical operation, and the absence of structural defects. Before use, qualified personnel should inspect the working ends and any locking mechanism for wear, deformation, corrosion, or other damage.
Cleaning, Sterilization, and Maintenance
If supplied as a reusable instrument, the Satinsky Vena Cava Clamp must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions and the healthcare facility's infection prevention protocols.
Cleaning should address the jaws, joints, and locking components, if present, to remove retained biological material. Following cleaning and before use, trained personnel should check the instrument for misalignment, damaged surfaces, corrosion, and mechanical defects.
The permitted sterilization method and processing parameters must follow the manufacturer's instructions for this specific product. Instruments that fail inspection should be removed from service until appropriately assessed.
Selecting the Correct Satinsky Vena Cava Clamp
When purchasing this 10-inch Satinsky clamp, verify its overall length, 4.0 cm jaw length, 9 mm jaw depth, jaw configuration, material, and intended application. These details help distinguish the product from other vascular clamps and support accurate ordering.
For hospitals, cardiovascular surgical centers, and medical instrument distributors, clear product identification helps maintain consistent inventory records and reduce confusion between similar instruments. Appropriate instrument selection, inspection, and validated reprocessing are essential to responsible surgical instrument management.
Key Features
Instrument type: Satinsky Vena Cava Clamp
Overall length: 10 inches (25.4 cm)
Jaw length: 4.0 cm (40 mm)
Jaw depth: 9 mm
Design: Satinsky-pattern vascular clamp
Surgical specialty: Cardiovascular and vascular surgery
Intended function: Controlled vascular clamping in appropriate procedures
Working end: Angled jaw pattern; verify exact geometry with the supplier
Material: Confirm exact composition with the manufacturer
Professional use: Intended for qualified surgical personnel
Maintenance: Requires regular inspection and appropriate care
Sterilization: Follow validated manufacturer instructions
Product Specifications
Specification | Details |
|---|---|
Product Name | Satinsky Vena Cava Clamp |
Overall Length | 10 inches |
Metric Length | 25.4 cm |
Jaw Length | 4.0 cm (40 mm) |
Jaw Depth | 9 mm |
Instrument Category | Vascular surgical clamp |
Pattern | Satinsky |
Specialty | Cardiovascular and vascular surgery |
Material | To be confirmed by manufacturer |
Jaw Surface | To be confirmed |
Locking Mechanism | To be confirmed |
Reusable Status | Confirm product labeling |
Sterilization Method | Follow manufacturer instructions |
Frequently Asked Questions
1. What is a 10″ Satinsky Vena Cava Clamp used for?
A Satinsky Vena Cava Clamp is a specialized vascular instrument used in selected procedures requiring controlled clamping of blood vessels. Its precise application depends on the model's design and the surgical technique.
2. What are the jaw dimensions of this Satinsky clamp?
The stated jaw length is 4.0 cm (40 mm), and the jaw depth is 9 mm.
3. What is the overall length of this vascular clamp?
The overall length is 10 inches, equivalent to 25.4 cm.
4. What is distinctive about a Satinsky vascular clamp?
The Satinsky pattern is associated with angled jaws that can facilitate access to selected vascular structures and support specific clamping techniques, including partial occlusion when appropriate.
5. What material is used to manufacture this clamp?
The exact material grade of this model should be confirmed with the supplier. Medical-grade stainless steel is commonly used for reusable cardiovascular surgical instruments.
6. Can the Satinsky Vena Cava Clamp be sterilized?
If the instrument is labeled as reusable, it must be cleaned and sterilized according to the manufacturer's validated instructions and the healthcare facility's approved reprocessing procedures.
7. How should I select the correct Satinsky clamp size?
Compare the overall length, jaw length, jaw depth, jaw configuration, and intended surgical application. Confirm the specifications with the supplier to ensure the instrument matches the requirements of the intended procedure.