10″ Debakey Tangential Occl Clamp – 5.5cm long 1.5cm deep
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-32181
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-32181AISI 420 Martensitic

10″ Debakey Tangential Occlusion Clamp 5.5cm Long

4.9 / 5.0•18 Verified OR Evaluations
$348.00$371.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $23.00 (6% OFF)
  • 10″ Debakey Tangential Occlusion Clamp designed with a straight configuration for controlled partial occlusion of major vessels.
  • 5.5 cm long jaws with 1.5 cm depth provide a defined clamping profile for cardiovascular procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a straight occlusion clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 10″ Debakey Tangential Occlusion Clamp is a specialized cardiovascular instrument designed for controlled partial occlusion of major vessels. Its 5.5 cm long jaws with a 1.5 cm depth provide even pressure distribution while minimizing vessel trauma during surgical procedures.

With an overall length of 10 inches and a 1.5 cm jaw depth, this occlusion clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach the vessel from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 10-inch overall length for controlled manual handling.
  • 5.5 cm long jaws with 1.5 cm depth provide a defined clamping profile.
  • Atraumatic design minimizes vessel injury.
  • Designed for controlled partial occlusion of major vessels.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Debakey pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeDebakey Tangential Occlusion Clamp
Overall Length10″
Working End / Blade / Jaw5.5 cm long jaws with 1.5 cm depth
ConfigurationStraight
Primary FunctionControlled Partial Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 10″ Debakey Tangential Occlusion Clamp combines a 10-inch overall length with 5.5 cm long jaws and 1.5 cm depth.
Its defined working profile is intended for controlled partial occlusion in cardiovascular applications.

Design & Function

The Debakey Tangential Occlusion Clamp features a straight working configuration designed to provide a specialized orientation during vascular procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 5.5 cm long jaws with 1.5 cm depth provide a defined clamping profile, while the 10-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a straight occlusion clamp.

Surgical Applications

The 10″ Debakey Tangential Occlusion Clamp may be used for cardiovascular and vascular surgery applications involving controlled partial occlusion of major vessels. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Debakey Tangential Occlusion Clamp before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Tangential Occlusion Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Debakey Tangential Occlusion Clamp?
The overall length is 10 inches.

2. What is the working end / blade or tip design of the instrument?
It features 5.5 cm long jaws with 1.5 cm depth.

3. Is this Debakey Tangential Occlusion Clamp curved or straight?
It features a Straight configuration.

4. What is a Debakey Tangential Occlusion Clamp used for?
It is designed for controlled partial occlusion in cardiovascular applications.

5. What clinical advantage does the atraumatic design provide?
The atraumatic design minimizes vessel injury during occlusion.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a straight occlusion clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Debakey Tangential Occlusion Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.