10″ Reul Aorta Clamp – Partial Occlusion – 2×2 vascular teeth
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33374
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-33374AISI 420 Martensitic

10″ Reul Aorta Clamp Partial Occlusion 2×2 Vascular Teeth

4.9 / 5.0•18 Verified OR Evaluations
$327.00$357.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $30.00 (8% OFF)
  • 10″ Reul Aorta Clamp designed with a partial occlusion configuration for controlled blood flow during cardiovascular procedures.
  • 2×2 vascular teeth provide a defined clamping profile for cardiovascular applications.
  • Partial occlusion design supports a specialized working orientation within the operative field.
  • Suitable for cardiac, vascular, and reconstructive surgery applications requiring a partial occlusion clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 10″ Reul Aorta Clamp is a specialized cardiovascular instrument designed for partial occlusion of the aorta during cardiovascular and thoracic procedures. Its 2×2 Debakey-style vascular teeth provide a secure yet atraumatic grip, allowing controlled blood flow while maintaining vessel integrity.

With an overall length of 10 inches and a 2×2 vascular tooth configuration, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach the vessel from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 10-inch overall length for controlled manual handling.
  • 2×2 vascular teeth provide a defined clamping profile.
  • Partial occlusion configuration for specialized working orientation.
  • Designed for controlled blood flow during cardiovascular procedures.
  • Suitable for cardiac, vascular, and reconstructive surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Reul pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeReul Aorta Clamp
Overall Length10″
Working End / Blade / Jaw2×2 Vascular Teeth
ConfigurationPartial Occlusion
Primary FunctionControlled Blood Flow
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Thoracic Surgery

The 10″ Reul Aorta Clamp combines a 10-inch overall length with a 2×2 vascular tooth configuration and partial occlusion design.
Its defined working profile is intended for controlled blood flow in cardiovascular applications.

Design & Function

The Reul Aorta Clamp features a partial occlusion configuration designed to provide a specialized orientation during cardiovascular procedures. The 2×2 vascular teeth can assist in positioning the working end according to the requirements of the operative field.

The 2×2 vascular teeth provide a defined clamping profile, while the 10-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a partial occlusion instrument.

Surgical Applications

The 10″ Reul Aorta Clamp may be used for cardiovascular and thoracic surgery applications involving partial occlusion of the aorta. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Reul Aorta Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Reul Aorta Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Reul Aorta Clamp?
The overall length is 10 inches.

2. What is the working end / blade or tip design of the instrument?
It features 2×2 vascular teeth.

3. Is this Reul Aorta Clamp curved or straight?
It features a partial occlusion configuration.

4. What is a Reul Aorta Clamp used for?
It is designed for controlled blood flow in cardiovascular applications.

5. What clinical advantage does the partial occlusion design provide?
The partial occlusion design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and thoracic surgery applications where a partial occlusion Reul Aorta Clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Reul Aorta Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.