11 3/4″ Desjardins Gall Stone Scoop 18 Fr Flexible
Direct Manufacturer Pricing • Tax Exclusive
- 11 3/4″ Desjardins Gall Stone Scoop 18 Fr Flexible designed with a flexible configuration for atraumatic gallstone extraction.
- 18 Fr working diameter provides a defined extraction profile for biliary procedures.
- Flexible design supports a specialized working orientation within the operative field.
- Suitable for biliary and cholecystectomy applications requiring a flexible Gall Stone Scoop.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 11 3/4″ Desjardins Gall Stone Scoop 18 Fr Flexible is a specialized surgical instrument designed for atraumatic extraction of gallstones during cholecystectomy and biliary procedures. Its flexible shaft allows precise maneuvering within the gallbladder or bile ducts, while the scoop tip securely captures stones for removal.
With an overall length of 11 3/4 inches and an 18 Fr diameter, this Gall Stone Scoop provides a defined extraction profile for biliary applications. The flexible design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 11 3/4-inch overall length for controlled manual handling.
- 18 Fr working diameter provides a defined extraction profile.
- Flexible configuration for specialized working orientation.
- Designed for atraumatic gallstone extraction.
- Suitable for biliary and cholecystectomy applications.
- Supports positioning of the working end within the operative field.
- Specialized Desjardins pattern for professional biliary instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Desjardins Gall Stone Scoop |
| Overall Length | 11 3/4″ |
| Working End / Blade / Jaw | 18 Fr |
| Configuration | Flexible |
| Primary Function | Atraumatic Gallstone Extraction |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Biliary / Cholecystectomy |
The 11 3/4″ Desjardins Gall Stone Scoop 18 Fr Flexible combines a 11 3/4-inch overall length with an 18 Fr diameter and flexible configuration.
Its defined working profile is intended for atraumatic gallstone extraction in biliary applications.
Design & Function
The Desjardins Gall Stone Scoop features a flexible working configuration designed to provide a specialized orientation during gallstone extraction. The flexible shaft can assist in positioning the scoop tip according to the requirements of the operative field.
The 18 Fr working diameter provides a defined extraction profile, while the 11 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for biliary procedures requiring a flexible instrument type.
Surgical Applications
The 11 3/4″ Desjardins Gall Stone Scoop 18 Fr Flexible may be used for biliary and cholecystectomy applications involving atraumatic extraction of gallstones. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Gall Stone Scoop before use, paying particular attention to the working end, scoop tip, and flexible shaft. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Gall Stone Scoop appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Gall Stone Scoop?
The overall length is 11 3/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 18 Fr.
3. Is this Gall Stone Scoop flexible or rigid?
It features a flexible configuration.
4. What is a Gall Stone Scoop used for?
It is designed for controlled atraumatic gallstone extraction in biliary applications.
5. What clinical advantage does the flexible design provide?
The flexible design provides a specialized working orientation for positioning the scoop tip within the operative field.
6. Is this instrument suitable for biliary surgery?
It may be used in biliary and cholecystectomy applications where a flexible Gall Stone Scoop is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Gall Stone Scoop be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.