11″ Debakey Tangential Occlusion Clamp 7.5cm Long, 1.7cm Deep
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-84476
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ClampsSKU: SP-84476AISI 420 Martensitic

11″ Debakey Tangential Occlusion Clamp 7.5cm Long, 1.7cm Deep

4.9 / 5.0•18 Verified OR Evaluations
$85.00$110.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $25.00 (23% OFF)

The 11″ DeBakey Tangential Occlusion Clamp is a specialized vascular surgical instrument designed for tangential clamping applications. It features a 7.5cm long jaw with a stated depth of 1.7cm, making it suitable for consideration in vascular and cardiovascular instrument sets.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 11″ DeBakey Tangential Occlusion Clamp, 7.5cm Long, 1.7cm Deep is a specialized surgical instrument intended for selected vascular and cardiovascular procedures. Its tangential occlusion design is associated with clamping a portion of a blood vessel while limiting obstruction to the remaining vessel lumen, depending on the instrument's construction and intended use. The stated dimensions help healthcare professionals and procurement teams identify the required clamp configuration.

DeBakey-Style Instrument Design

DeBakey-style instruments are commonly associated with vascular surgery, where controlled handling and appropriate jaw geometry are important. This clamp is identified by its DeBakey design and tangential occlusion function. Its configuration should be evaluated against the requirements of the intended procedure and the manufacturer's specifications.

Tangential occlusion clamps may be selected for procedures that require temporary control of blood flow in a limited section of a vessel. The exact application depends on the clamp's design, jaw characteristics, and approved intended use. Clinical decisions should always be made by qualified healthcare professionals.

Jaw Dimensions and Configuration

This instrument has a stated jaw length of 7.5cm and a jaw depth of 1.7cm. These measurements are useful when comparing surgical instruments, assembling procedure-specific sets, or replacing an existing clamp.

The jaw dimensions can influence access, positioning, and the area of the vessel that can be engaged. Buyers should verify how the manufacturer defines jaw length and depth, as measurement conventions may vary. Additional details, such as jaw curvature, serration pattern, clamping pressure, and handle configuration, should be confirmed before purchase.

Applications in Vascular and Cardiovascular Surgery

Tangential occlusion clamps are used in selected vascular procedures where partial or localized vessel clamping is required. Depending on the particular instrument design, these clamps may be considered for vascular reconstruction and other cardiovascular applications requiring controlled vessel occlusion.

Not every tangential occlusion clamp is suitable for every vessel or procedure. Vessel size, tissue condition, jaw profile, and the surgical technique must be considered when selecting an instrument. Always follow the manufacturer's instructions and the judgment of the qualified surgical team.

Material, Sterilization, and Maintenance

The material composition and reusable status of this specific model have not been provided. Confirm the material grade, surface finish, and sterilization compatibility with the manufacturer or supplier. If the clamp is reusable, follow validated cleaning, inspection, and sterilization instructions and the healthcare facility's infection-control protocols.

Before use, trained personnel should inspect the instrument for corrosion, surface damage, jaw misalignment, and proper closure. Any clamp that shows signs of damage or malfunction should be removed from service.

The 11″ DeBakey Tangential Occlusion Clamp is a specification-focused option for medical procurement teams, surgical instrument distributors, and healthcare facilities sourcing specialized vascular instruments. Confirming the dimensions and manufacturer details helps ensure the instrument matches the clinical and inventory requirements.

Key Features

  • DeBakey-style tangential occlusion clamp

  • Designed for selected vascular clamping applications

  • Overall length: 11 inches

  • Jaw length: 7.5cm

  • Jaw depth: 1.7cm

  • Intended category: vascular and cardiovascular surgical instruments

  • Suitable for evaluation in specialized vascular instrument sets

  • Jaw geometry and surface pattern to be confirmed

  • Material composition to be verified with the supplier

  • Reprocessing according to manufacturer instructions

Product Specifications

Specification

Details

Product Name

DeBakey Tangential Occlusion Clamp

Instrument Type

Tangential Occlusion Clamp

Design

DeBakey style

Overall Length

11 inches

Jaw Length

7.5cm

Jaw Depth

1.7cm

Specialty

Vascular and Cardiovascular Surgery

Intended Function

Tangential vessel occlusion, subject to intended-use specifications

Jaw Profile

Confirm with manufacturer

Material

Confirm with manufacturer or supplier

Reusable Status

Confirm with supplier

Sterilization

Follow validated manufacturer instructions

Product Code / SKU

To be assigned

Frequently Asked Questions

1. What is an 11″ DeBakey Tangential Occlusion Clamp used for?

It is a specialized vascular clamp intended for selected procedures requiring tangential or localized vessel occlusion. Its specific application depends on the model's design and manufacturer instructions.

2. What is the overall length of this clamp?

The stated overall length is 11 inches.

3. What are the jaw dimensions?

The product specifications provided list a jaw length of 7.5cm and a jaw depth of 1.7cm.

4. What does tangential occlusion mean?

Tangential occlusion refers to clamping a portion of a vessel rather than necessarily closing the entire vessel lumen. The exact effect depends on the instrument design and its use during the procedure.

5. Is this clamp suitable for cardiovascular surgery?

It may be considered for appropriate vascular or cardiovascular procedures if its specifications and intended use meet the clinical requirements.

6. What material is the clamp made from?

The material grade is not specified in the supplied product title. Confirm it with the manufacturer or supplier before ordering.

7. Can the clamp be sterilized and reused?

Reusable status and sterilization compatibility should be confirmed with the supplier. Follow the manufacturer's validated cleaning and sterilization instructions.

8. What should buyers verify before purchasing?

Confirm the overall length, jaw length, jaw depth, jaw profile, material, intended use, and reprocessing requirements to ensure the clamp matches the intended surgical application.