12″ Spurling IVD Rongeur 5×10mm Straight
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-52800
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-52800AISI 420 Martensitic

12″ Spurling IVD Rongeur 5×10mm Straight

4.9 / 5.0•18 Verified OR Evaluations
$1100.00$1200.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $100.00 (8% OFF)
  • 12″ Spurling IVD Rongeur designed with a straight configuration for controlled disc extraction.
  • 5×10 mm jaw dimensions provide a defined grasping profile for neurosurgical procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal surgery applications requiring a straight rongeur.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 12″ Spurling IVD Rongeur is a specialized neurosurgical instrument designed for firm and controlled extraction of intervertebral disc material. Its straight jaw configuration provides direct access and strong tissue engagement, while the extended length enhances reach during deep spinal procedures.

With an overall length of 12 inches and 5×10 mm jaw dimensions, this rongeur provides a defined grasping profile for neurosurgical applications. The straight design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 12-inch overall length for enhanced reach during deep spinal procedures.
  • 5×10 mm jaw dimensions provide a defined grasping profile.
  • Straight configuration for direct access to intervertebral discs.
  • Designed for controlled extraction of intervertebral disc material.
  • Suitable for neurosurgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Spurling pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeSpurling IVD Rongeur
Overall Length12″
Working End / Blade / Jaw5×10 mm
ConfigurationStraight
Primary FunctionDisc Extraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 12″ Spurling IVD Rongeur combines a 12-inch overall length with 5×10 mm jaw dimensions and a straight configuration.
Its defined working profile is intended for controlled extraction of intervertebral disc material in neurosurgical applications.

Design & Function

The Spurling IVD Rongeur features a straight working configuration designed to provide a specialized orientation during disc extraction. The straight jaw design can assist in positioning the working end according to the requirements of the operative field.

The 5×10 mm jaw profile provides a defined grasping profile, while the 12-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a straight rongeur.

Surgical Applications

The 12″ Spurling IVD Rongeur may be used for neurosurgical and spinal surgery applications involving the extraction of intervertebral disc material. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Rongeur?
The overall length is 12 inches.

2. What is the working end / blade or tip design of the instrument?
It features 5×10 mm jaw dimensions.

3. Is this Rongeur curved or straight?
It features a Straight configuration.

4. What is a Rongeur used for?
It is designed for controlled disc extraction in neurosurgical applications.

5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal surgery applications where a straight rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.