2 3/4″ Satinsky Bulldog Clamp
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-32424
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-32424AISI 420 Martensitic

2 3/4″ Satinsky Bulldog Clamp Atraumatic Design

4.9 / 5.0•18 Verified OR Evaluations
$285.00$310.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $25.00 (8% OFF)
  • 2 3/4″ Satinsky Bulldog Clamp designed with a compact configuration for temporary vessel occlusion.
  • Atraumatic jaw design provides a defined clamping profile for cardiovascular procedures.
  • Compact design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and surgical applications requiring a compact clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 2 3/4″ Satinsky Bulldog Clamp is a specialized cardiovascular instrument designed for temporary vessel occlusion in confined surgical spaces. Its compact size and atraumatic jaws allow precise clamping while minimizing vessel trauma.

With an overall length of 2 3/4 inches and a durable construction, this clamp provides a defined clamping profile for cardiovascular applications. The atraumatic design allows the working end to approach vessels safely, supporting controlled manual manipulation during procedures.

Key Features

  • 2 3/4-inch overall length for precision handling.
  • Atraumatic jaw design for safe vessel occlusion.
  • Compact configuration for specialized working orientation.
  • Designed for temporary clamping in small or confined areas.
  • Suitable for cardiovascular applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Satinsky pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeSatinsky Bulldog Clamp
Overall Length2 3/4″
Working End / Blade / JawAtraumatic jaws
ConfigurationCompact
Primary FunctionTemporary Vessel Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular

The 2 3/4″ Satinsky Bulldog Clamp combines a 2 3/4-inch overall length with atraumatic jaws and a compact configuration.
Its defined working profile is intended for temporary vessel occlusion in cardiovascular applications.

Design & Function

The Satinsky Bulldog Clamp features a compact working configuration designed to provide a specialized orientation during vessel clamping. The atraumatic jaw design can assist in positioning the working end according to the requirements of the operative field.

The atraumatic jaws provide a defined clamping profile, while the 2 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a compact instrument.

Surgical Applications

The 2 3/4″ Satinsky Bulldog Clamp may be used for cardiovascular and surgical applications involving temporary vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Satinsky Bulldog Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Satinsky Bulldog Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Clamp?
The overall length is 2 3/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features atraumatic jaws.

3. Is this Clamp curved or straight?
It features a compact configuration.

4. What is a Clamp used for?
It is designed for controlled temporary vessel occlusion in cardiovascular applications.

5. What clinical advantage does the atraumatic design provide?
The atraumatic design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and surgical applications where a compact clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.