
26cm Weber Aortic Clamp Right
Direct Manufacturer Pricing • Tax Exclusive
- 26cm Weber Aortic Clamp Right designed with a right-sided configuration for aortic occlusion.
- Atraumatic jaw design provides a defined clamping profile for cardiovascular procedures.
- Right-sided design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and aortic surgery applications requiring a right-sided aortic clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 26cm Weber Aortic Clamp Right is a specialized cardiovascular instrument designed for occlusion of the aorta during major cardiovascular procedures. Its extended length allows secure reach into deep surgical fields, while the atraumatic jaws ensure safe vessel control and minimal trauma.
With an overall length of 26 cm and a right-sided configuration, this aortic clamp provides excellent visibility, control, and stability during complex aortic operations. The design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 26 cm overall length for secure reach into deep surgical fields.
- Atraumatic jaw design provides safe vessel control.
- Right-sided configuration for specialized working orientation.
- Designed for occlusion of the aorta during cardiovascular procedures.
- Suitable for major cardiovascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Weber pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Weber Aortic Clamp |
| Overall Length | 26 cm |
| Working End / Blade / Jaw | Atraumatic jaws |
| Configuration | Right-sided |
| Primary Function | Aortic Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular Surgery |
The 26cm Weber Aortic Clamp Right combines a 26 cm overall length with atraumatic jaws and a right-sided configuration.
Its defined working profile is intended for aortic occlusion in cardiovascular applications.
Design & Function
The Weber Aortic Clamp features a right-sided working configuration designed to provide a specialized orientation during aortic occlusion. The atraumatic jaw design can assist in positioning the working end according to the requirements of the operative field.
The jaw profile provides a defined clamping profile, while the 26 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a right-sided aortic clamp.
Surgical Applications
The 26cm Weber Aortic Clamp Right may be used for cardiovascular and aortic surgery applications involving occlusion of the aorta. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the aortic clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the aortic clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Aortic Clamp?
The overall length is 26 cm.
2. What is the working end / jaw design of the instrument?
It features atraumatic jaws.
3. Is this Aortic Clamp right-sided or left-sided?
It features a right-sided configuration.
4. What is a Weber Aortic Clamp used for?
It is designed for controlled aortic occlusion in cardiovascular applications.
5. What clinical advantage does the atraumatic jaw design provide?
The design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and aortic surgery applications where a right-sided aortic clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Aortic Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
