2.7mm Surgical Plate & Locking Screw Set, L/R
Direct Manufacturer Pricing • Tax Exclusive
The Surgical Plate and Locking Screw Set features 2.7mm fixation components with left- and right-sided plate options and 2–4 hole configurations. The 50-piece set is designed for orthopedic fixation applications where the plate geometry and locking screws match the surgical requirements. Confirm the anatomical plate type, screw dimensions, material, and complete set contents before ordering.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Surgical Plate and Locking Screw Set – 2.7mm, L/R, 2–4 Holes, 50 Pieces is an orthopedic fixation set designed to provide a selection of plates and compatible locking screws for suitable fracture fixation procedures. The set includes left- and right-sided options and plates with 2, 3, or 4 holes, as indicated by the stated 2–4 hole range. Its total configuration is listed as 50 pieces.
The precise anatomical application, plate profile, and distribution of components are not specified in the product title. These details should be confirmed with the manufacturer or supplier to ensure the set matches the intended procedure.
Plate Design and Hole Configurations
Orthopedic fixation plates are available in different shapes and sizes to accommodate anatomical requirements and fracture patterns. The 2–4 hole configurations provide options for selecting a plate according to the required fixation length and available bone. The number of holes alone does not establish the plate's overall length, working length, or suitability for a particular fracture.
Left- and right-sided plates are designed to correspond to a specified anatomical side when the plate system uses side-specific configurations. The exact anatomical location and shape of these plates must be verified before purchase. Buyers should request the manufacturer's product specifications and plate illustrations to identify the intended application accurately.
2.7mm Locking Screw System
The 2.7mm designation identifies the stated size associated with the set, but the title does not clarify whether it refers to the compatible screw diameter, the plate system, or both. This specification should be confirmed before ordering.
Locking fixation systems use screws designed to engage with the plate's locking mechanism. When compatible components are assembled correctly, the locking interface creates a fixed-angle relationship between the screw and plate. Screw diameter, length, thread design, head configuration, and locking compatibility must match the manufacturer's specifications.
Do not assume that screws from different systems are interchangeable based only on a nominal size. Confirm the approved screw range and instrumentation before clinical use.
Set Configuration and Components
The set is described as containing 50 pieces. However, the title does not provide a detailed breakdown of the number of plates, screw quantities, individual lengths, or any additional components. An itemized inventory is important for confirming that the set contains the required plate configurations and enough compatible screws for its intended application.
Before purchase, verify the number of left- and right-sided plates, the distribution of 2-, 3-, and 4-hole options, the screw sizes supplied, and whether any storage tray or accessories are included. These details should not be inferred from the total piece count.
Material and Orthopedic Applications
The material is not specified in the product title. Orthopedic plates and screws may be manufactured from different implant materials, and their composition affects the applicable handling, processing, and documentation requirements. Confirm the material grade and relevant manufacturer documentation before adding the set to an implant inventory.
The set may be considered for selected orthopedic fixation applications when its verified design is appropriate for the anatomical location and fracture pattern. Implant selection and use should be determined by a qualified orthopedic surgeon according to the patient's anatomy, clinical needs, and the manufacturer's intended-use instructions.
Inspection, Handling, and Storage
Before use, check the product identity, component sizes, packaging integrity, and traceability documentation. Inspect plates and screws for damage, corrosion, deformation, or other visible defects. Components should only be used together when their compatibility is confirmed by the manufacturer.
The title does not specify whether the set is supplied sterile, whether components are single-use, or which sterilization procedures are approved. Follow the manufacturer's labeling for storage, handling, and preparation. Use compatible instrumentation and adhere to the applicable clinical and regulatory requirements.
The Surgical Plate and Locking Screw Set – 2.7mm, L/R, 2–4 Holes, 50 Pieces offers a compact assortment of orthopedic fixation components. Confirm the anatomical plate design, material, screw specifications, and itemized contents before ordering.
Key Features
Orthopedic surgical plate and locking screw set
Stated 50-piece configuration
2.7mm size designation
Left- and right-sided plate options
2-, 3-, and 4-hole configurations indicated
Designed for compatible orthopedic fixation applications
Locking screw compatibility requires verification
Anatomical plate profile is not specified
Material and individual component dimensions are not specified
Sterility and packaging details require confirmation
Product Specifications
Specification | Details |
|---|---|
Product Name | Surgical Plate & Locking Screw Set |
Instrument Category | Orthopedic fixation implant set |
Total Set Size | 50 pieces |
Size Designation | 2.7mm |
Plate Orientation | Left and right |
Hole Configurations | 2, 3, and 4 holes |
Screw Type | Locking screws |
Anatomical Application | Not specified |
Plate Profile | Not specified |
Plate Dimensions | Not specified |
Screw Diameters and Lengths | Confirm with manufacturer |
Material | Not specified |
Sterility | Not specified |
Single-Use Status | Confirm with manufacturer |
Storage and Handling | Follow manufacturer instructions |
Frequently Asked Questions
1. What is the Surgical Plate and Locking Screw Set used for?
It is designed for selected orthopedic fixation procedures using compatible plates and locking screws. Its suitability depends on the anatomical plate design and the requirements of the procedure.
2. How many pieces are included in the set?
The product title specifies 50 pieces. Request an itemized contents list to confirm the number of plates, screws, and any additional components.
3. What does 2.7mm mean in this set?
It is the stated size designation. Confirm whether it refers to the screw diameter, the plate system, or both in the manufacturer's specifications.
4. What plate configurations are available?
The title identifies left- and right-sided options with 2-, 3-, and 4-hole configurations. Exact plate shapes and dimensions are not specified.
5. Are the locking screws compatible with all 2.7mm plates?
No. Compatibility depends on the plate's locking design, screw thread, diameter, and manufacturer specifications. Use only confirmed compatible components.
6. What material are the plates and screws made from?
The material is not specified in the title. Confirm the material grade and supporting documentation with the manufacturer or supplier.
7. Is the set supplied sterile?
Sterile status is not specified. Check the manufacturer's packaging and labeling before clinical use.
8. What should I verify before purchasing this set?
Confirm the anatomical application, plate profiles, hole configurations, screw dimensions, material, complete 50-piece inventory, compatibility, and processing requirements.