3 1/2″ Gregory Bulldog Clamp 55mm Angled
Direct Manufacturer Pricing • Tax Exclusive
- 3 1/2″ Gregory Bulldog Clamp designed with an angled configuration for temporary vascular occlusion.
- 55 mm angled jaw provides a defined clamping profile for cardiovascular procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring an angled clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 3 1/2″ Gregory Bulldog Clamp is a specialized cardiovascular instrument designed for temporary vascular occlusion with minimal trauma. Its angled 55 mm jaw provides a distinct working orientation that can assist with positioning the clamp within the operative field.
With an overall length of 3 1/2 inches and a 1x2 atraumatic teeth configuration, this Bulldog Clamp provides a defined clamping profile for vascular applications. The angled design allows the working end to approach delicate vessels from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 3 1/2-inch overall length for controlled manual handling.
- 1x2 teeth provides a secure, non-slip grasp.
- Angled configuration for improved access and visibility.
- Designed for temporary vascular occlusion with minimal trauma.
- Suitable for vascular and cardiac surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Gregory pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Gregory Bulldog Clamp |
| Overall Length | 3 1/2″ |
| Working End / Blade / Jaw | 55 mm Angled Jaw |
| Configuration | Angled |
| Primary Function | Temporary Vascular Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 3 1/2″ Gregory Bulldog Clamp combines a 3 1/2-inch overall length with a 55 mm angled jaw.
Its defined working profile is intended for temporary vascular occlusion in cardiovascular applications.
Design & Function
The Gregory Bulldog Clamp features an angled working configuration designed to provide a specialized orientation during vascular procedures. The angled jaw design can assist in positioning the clamp according to the requirements of the operative field.
The 55 mm jaw provides a defined clamping profile, while the 3 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled clamp.
Surgical Applications
The 3 1/2″ Gregory Bulldog Clamp may be used for cardiovascular and vascular surgery applications involving temporary vascular occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Bulldog Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Bulldog Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Bulldog Clamp?
The overall length is 3 1/2 inches.
2. What is the working end / jaw design of the instrument?
It features 55 mm Angled Jaw.
3. Is this Bulldog Clamp angled or straight?
It features an angled configuration.
4. What is a Bulldog Clamp used for?
It is designed for controlled temporary vascular occlusion in cardiovascular applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where an angled clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Bulldog Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.