4 1/4″ Lambert Sleeve Spreader – 90° jaws
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-65074
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-65074AISI 420 Martensitic

4 1/4″ Lambert Sleeve Spreader 90° Jaws

4.9 / 5.0•18 Verified OR Evaluations
$158.00$178.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (11% OFF)
  • 4 1/4″ Lambert Sleeve Spreader designed with an angled configuration for controlled tissue separation.
  • 90° jaw dimension provides a defined clamping profile for ophthalmic procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for ophthalmic and microsurgery applications requiring a specialized sleeve spreader.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4 1/4″ Lambert Sleeve Spreader is a specialized ophthalmic instrument designed for expanding or holding open delicate tubular structures during microsurgical procedures. Its 90° angled jaws provide a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 4 1/4 inches and a robust design, this sleeve spreader provides a defined clamping profile for ophthalmic applications. The ergonomic handle allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 4 1/4-inch overall length for controlled manual handling.
  • 90° jaw dimension provides a defined clamping profile.
  • Angled configuration for specialized working orientation.
  • Designed for controlled tissue separation and access.
  • Suitable for ophthalmic and microsurgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Lambert pattern for professional ophthalmic instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeLambert Sleeve Spreader
Overall Length4 1/4″
Working End / Blade / Jaw90° Jaws
ConfigurationAngled
Primary FunctionTissue Separation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOphthalmic / Microsurgery

The 4 1/4″ Lambert Sleeve Spreader combines a 4 1/4-inch overall length with 90° jaws and an angled configuration.
Its defined working profile is intended for controlled tissue separation in ophthalmic applications.

Design & Function

The Lambert Sleeve Spreader features an angled working configuration designed to provide a specialized orientation during microsurgical procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 90° jaw profile provides a defined clamping profile, while the 4 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a specialized sleeve spreader.

Surgical Applications

The 4 1/4″ Lambert Sleeve Spreader may be used for ophthalmic and microsurgery applications involving the expansion or holding open of delicate tubular structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the sleeve spreader before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the sleeve spreader appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Sleeve Spreader?
The overall length is 4 1/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features 90° jaws.

3. Is this Sleeve Spreader curved or straight?
It features an angled configuration.

4. What is a Sleeve Spreader used for?
It is designed for controlled tissue separation in ophthalmic applications.

5. What clinical advantage does the angled design provide?
The angled configuration provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and microsurgery applications where a 90° jaw sleeve spreader is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Sleeve Spreader be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.