4 3/4″ Gregory “Soft” Bulldog Clamp – Left
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-31713
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-31713AISI 420 Martensitic

4 3/4″ Gregory Bulldog Clamp Left

4.9 / 5.0•18 Verified OR Evaluations
$289.00$305.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $16.00 (5% OFF)
  • 4 3/4″ Gregory Bulldog Clamp Left designed with a soft-pressure configuration for temporary vascular occlusion.
  • Left-oriented jaw design provides a defined clamping profile for cardiovascular procedures.
  • Soft-pressure design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a soft-pressure clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4 3/4″ Gregory Bulldog Clamp Left is a specialized cardiovascular instrument designed for temporary vascular occlusion where gentle, low-pressure clamping is required. Its soft-pressure spring mechanism and left-oriented jaw configuration provide atraumatic vessel control, making it ideal for delicate vascular and peripheral procedures.

With an overall length of 4 3/4 inches and a left-oriented jaw design, this Bulldog Clamp provides a defined clamping profile for cardiovascular applications. The soft-pressure design allows the working end to approach vessels with minimal trauma, supporting controlled manual manipulation during procedures.

Key Features

  • 4 3/4-inch overall length for controlled manual handling.
  • Left-oriented jaw design provides anatomical precision.
  • Soft-pressure configuration minimizes vessel trauma.
  • Designed for temporary vascular occlusion.
  • Suitable for delicate vascular and peripheral procedures.
  • Supports positioning of the working end within the operative field.
  • Specialized Gregory pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeGregory Bulldog Clamp
Overall Length4 3/4″
Working End / Blade / JawLeft-oriented jaw
ConfigurationSoft-pressure
Primary FunctionTemporary Vascular Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular

The 4 3/4″ Gregory Bulldog Clamp Left combines a 4 3/4-inch overall length with a left-oriented jaw design and soft-pressure configuration.
Its defined working profile is intended for temporary vascular occlusion in cardiovascular applications.

Design & Function

The Gregory Bulldog Clamp features a soft-pressure working configuration designed to provide a specialized orientation during vascular procedures. The left-oriented jaw design can assist in positioning the working end according to the requirements of the operative field.

The left-oriented jaw provides a defined clamping profile, while the 4 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a soft-pressure clamp.

Surgical Applications

The 4 3/4″ Gregory Bulldog Clamp Left may be used for cardiovascular and vascular surgery applications involving temporary vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Bulldog Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Bulldog Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Bulldog Clamp?
The overall length is 4 3/4 inches.

2. What is the working end / jaw design of the instrument?
It features left-oriented jaw.

3. Is this Bulldog Clamp curved or straight?
It features a soft-pressure configuration.

4. What is a Bulldog Clamp used for?
It is designed for controlled temporary vascular occlusion in cardiovascular applications.

5. What clinical advantage does the soft-pressure design provide?
The soft-pressure design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a soft-pressure clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Bulldog Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.