4 3/4″ Tessier Maxillo Double Curve Retractor – nasal bridge
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-62934
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-62934AISI 420 Martensitic

4 3/4″ Tessier Maxillo Double Curve Retractor – Nasal Bridge

4.9 / 5.0•18 Verified OR Evaluations
$175.00$195.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (10% OFF)
  • 4 3/4″ Tessier Maxillo Double Curve Retractor – Nasal Bridge designed with a double curved configuration for controlled retraction during nasal bridge and midface surgeries.
  • Double curve profile provides a defined retraction profile for maxillofacial procedures.
  • Double curved design supports a specialized working orientation within the operative field.
  • Suitable for maxillofacial and reconstructive surgery applications requiring a double curved retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4 3/4″ Tessier Maxillo Double Curve Retractor – Nasal Bridge is a specialized maxillofacial instrument designed for controlled retraction during delicate nasal bridge and midface surgeries. Its double-curved design conforms to the natural anatomical contours of the nasal and maxillary structures, allowing surgeons unobstructed access to the operative site.

With an overall length of 4 3/4 inches and a compact design, this retractor provides a defined retraction profile for maxillofacial applications. The double curve allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 4 3/4-inch overall length for controlled manual handling.
  • Double curve design provides a defined retraction profile.
  • Specialized configuration for optimal working orientation.
  • Designed for controlled retraction during nasal bridge and midface surgeries.
  • Suitable for maxillofacial and reconstructive surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Tessier pattern for professional maxillofacial instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeTessier Maxillo Double Curve Retractor
Overall Length4 3/4″
Working End / Blade / JawDouble curve profile
ConfigurationDouble Curved
Primary FunctionControlled Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeMaxillofacial / Reconstructive Surgery

The 4 3/4″ Tessier Maxillo Double Curve Retractor – Nasal Bridge combines a 4 3/4-inch overall length with a double curve design.
Its defined working profile is intended for controlled retraction in maxillofacial applications.

Design & Function

The Tessier Maxillo Double Curve Retractor features a double curved working configuration designed to provide a specialized orientation during nasal bridge and midface surgeries. The curvature can assist in positioning the working end according to the requirements of the operative field.

The double curve profile provides a defined retraction profile, while the 4 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for maxillofacial procedures requiring a specialized retractor.

Surgical Applications

The 4 3/4″ Tessier Maxillo Double Curve Retractor – Nasal Bridge may be used for maxillofacial and reconstructive surgery applications involving controlled retraction of the nasal and midface structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Tessier Maxillo Double Curve Retractor before use, paying particular attention to the working end and curvature. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Tessier Maxillo Double Curve Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Retractor?
The overall length is 4 3/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features double curve profile.

3. Is this Retractor curved or straight?
It features a double curved configuration.

4. What is a Retractor used for?
It is designed for controlled retraction in maxillofacial applications.

5. What clinical advantage does the double curve provide?
The double curve provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for maxillofacial surgery?
It may be used in maxillofacial and reconstructive surgery applications where a double curved retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.