4 3 4″ Baby Vascular Clamp 3.5mm Straight Jaws, Straight Shanks
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-81005
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-81005AISI 420 Martensitic

4 3/4″ Baby Vascular Clamp 3.5mm Straight Jaws, Straight Shanks

4.9 / 5.0•18 Verified OR Evaluations
$90.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $30.00 (25% OFF)

The 4¾″ Baby Vascular Clamp features 3.5mm straight jaws and straight shanks for specialized instrument handling in vascular surgery. Its compact configuration supports precise positioning for appropriate surgical applications. Confirm the jaw measurement, material, and intended use with the manufacturer before ordering.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4¾″ Baby Vascular Clamp with 3.5mm Straight Jaws and Straight Shanks is a compact surgical instrument designed for selected vascular applications. With an overall length of 4¾ inches, it provides a smaller instrument profile for procedures requiring a compact clamp configuration. Its straight jaws and straight shanks offer a direct alignment that may support controlled positioning, depending on the intended surgical task.

Straight Jaw Design

The straight jaw configuration distinguishes this model from vascular clamps featuring curved or angled jaws. Straight jaws provide a direct approach to the target area, which may be appropriate for specific instrument-handling requirements. The listed 3.5mm measurement should be verified with the supplier to establish whether it refers to jaw width, length, or another dimension.

Straight Shank Configuration

The straight shanks provide a linear arrangement between the handle and jaw assembly. This configuration can support direct instrument positioning where an offset shank is not required. Selection should be based on the anatomy, access requirements, and the manufacturer's documented intended use.

Applications in Vascular Surgery

Vascular clamps are used by trained surgical professionals for controlled handling of blood vessels during selected procedures. The appropriate instrument depends on its jaw geometry, dimensions, clamping characteristics, and intended clinical function. The term “Baby” generally identifies an instrument pattern or compact size category and should not be taken as confirmation that the product is specifically intended for pediatric surgery.

Instrument Quality and Care

Before purchasing, verify the construction material, exact jaw dimensions, locking or clamping mechanism, and approved reprocessing methods. Follow the manufacturer's instructions for cleaning, sterilization, inspection, and storage. Check jaw alignment and instrument function before use, and remove damaged instruments from service.

Key Features

  • Instrument type: Baby vascular clamp

  • Overall length: 4¾ inches

  • Jaw configuration: Straight

  • Specified jaw measurement: 3.5mm

  • Shank configuration: Straight

  • Compact design for selected vascular applications

  • Direct jaw alignment for appropriate instrument positioning

  • Intended for use by trained surgical professionals

  • Material and construction details to be confirmed with the supplier

  • Cleaning and sterilization requirements depend on manufacturer instructions

Product Specifications

Specification

Details

Product Name

Baby Vascular Clamp

Instrument Category

Vascular Surgical Instrument

Overall Length

4¾ inches (approximately 12.07 cm)

Jaw Measurement

3.5mm; exact dimension to be confirmed

Jaw Style

Straight

Shank Style

Straight

Instrument Pattern

Baby

Material

Confirm with supplier/manufacturer

Clamping Mechanism

Confirm with supplier/manufacturer

Sterilization Compatibility

Follow manufacturer instructions

Reusability

Confirm with supplier/manufacturer

Intended Application

Confirm against manufacturer documentation

Frequently Asked Questions

1. What is a 4¾″ Baby Vascular Clamp used for?

Vascular clamps are used for controlled handling of blood vessels during selected surgical procedures. The precise function of this particular model should be confirmed through manufacturer documentation.

2. What is the overall length of this clamp?

The specified overall length is 4¾ inches, approximately 12.07 cm.

3. What does the 3.5mm jaw measurement indicate?

The title specifies a 3.5mm jaw measurement but does not identify the exact dimension. Confirm whether it refers to jaw width, length, or another measurement with the supplier.

4. What is the benefit of straight jaws?

Straight jaws provide a direct jaw alignment and may be suitable for procedures where a curved or angled jaw is not required.

5. What are straight shanks?

Straight shanks follow a linear configuration between the handle and jaws, supporting direct positioning of the instrument.

6. Is this clamp intended for pediatric surgery?

The term “Baby” may describe the instrument's pattern or size category. Confirm pediatric suitability with the manufacturer before selecting it for that purpose.

7. What material is used to manufacture this clamp?

The material is not specified in the supplied title. Contact the supplier to confirm the material grade and construction details.

8. Can this vascular clamp be sterilized and reused?

Sterilization compatibility and reusability depend on the instrument's construction and manufacturer instructions. Follow the approved cleaning and reprocessing guidance for the specific model.