5 1/2″ Bunnell Dissecting Probe – angled tip
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33193
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-33193AISI 420 Martensitic

5 1/2″ Bunnell Dissecting Probe Angled Tip

4.9 / 5.0•18 Verified OR Evaluations
$35.00$63.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $28.00 (44% OFF)
  • 5 1/2″ Bunnell Dissecting Probe Angled Tip designed with an angled configuration for controlled tissue dissection and exploration.
  • Angled tip provides a defined dissection profile for neurosurgical procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and orthopedic applications requiring an angled dissecting probe.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5 1/2″ Bunnell Dissecting Probe Angled Tip is a specialized neurosurgical instrument designed for controlled tissue dissection and exploration during microsurgical, spinal, and orthopedic procedures. Its angled tip provides a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 5 1/2 inches and a precision angled tip, this dissecting probe provides a defined dissection profile for neurosurgical applications. The ergonomic design allows the working end to approach anatomical structures from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 5 1/2-inch overall length for controlled manual handling.
  • Angled tip provides a defined dissection profile.
  • Ergonomic design for specialized working orientation.
  • Designed for controlled tissue dissection and exploration.
  • Suitable for neurosurgical and orthopedic applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Bunnell pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeBunnell Dissecting Probe
Overall Length5 1/2″
Working End / Blade / JawAngled Tip
ConfigurationAngled
Primary FunctionTissue Dissection and Exploration
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical / Orthopedic

The 5 1/2″ Bunnell Dissecting Probe Angled Tip combines a 5 1/2-inch overall length with an angled tip.
Its defined working profile is intended for controlled tissue dissection and exploration in neurosurgical applications.

Design & Function

The Bunnell Dissecting Probe features an angled working configuration designed to provide a specialized orientation during tissue dissection. The angled tip can assist in positioning the working end according to the requirements of the operative field.

The angled tip provides a defined dissection profile, while the 5 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a dissecting probe.

Surgical Applications

The 5 1/2″ Bunnell Dissecting Probe Angled Tip may be used for neurosurgical and orthopedic applications involving controlled tissue dissection and exploration. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the dissecting probe before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the dissecting probe appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Dissecting Probe?
The overall length is 5 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features an angled tip.

3. Is this Dissecting Probe curved or straight?
It features an angled configuration.

4. What is a Dissecting Probe used for?
It is designed for controlled tissue dissection and exploration in neurosurgical applications.

5. What clinical advantage does the angled tip provide?
The angled tip provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and orthopedic applications where an angled dissecting probe is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Dissecting Probe be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.