5 1/2″ Garrett Vascular Dilator – set of 9
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-34406
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-34406AISI 420 Martensitic

5 1/2″ Garrett Vascular Dilator Set of 9

4.9 / 5.0•18 Verified OR Evaluations
$1055.00$1254.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $199.00 (16% OFF)
  • 5 1/2″ Garrett Vascular Dilator Set of 9 designed with a progressive configuration for controlled vessel dilation.
  • Smooth tapered tips provide a defined dilation profile for cardiovascular procedures.
  • Progressive design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and peripheral vascular applications requiring a progressive dilator.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5 1/2″ Garrett Vascular Dilator Set of 9 is a specialized cardiovascular instrument designed for progressive, atraumatic vessel dilation. Its smooth, tapered tips provide a distinct working orientation that can assist with gradual vessel expansion while minimizing trauma to delicate tissue.

With an overall length of 5 1/2 inches, this dilator set offers a complete range of sizes for effective dilation in cardiovascular and peripheral vascular procedures. The compact length ensures excellent maneuverability in confined operative fields, while the ergonomic handles provide superior tactile feedback and precise control during procedures.

Key Features

  • 5 1/2-inch overall length for enhanced maneuverability.
  • Set of 9 dilators provides a complete range of sizes for progressive dilation.
  • Smooth, tapered tip configuration for atraumatic vessel expansion.
  • Designed for controlled vessel dilation.
  • Suitable for cardiovascular and peripheral vascular applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Garrett pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeGarrett Vascular Dilator
Overall Length5 1/2″
Working End / Blade / JawSmooth tapered tips
ConfigurationProgressive
Primary FunctionVessel Dilation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Peripheral Vascular

The 5 1/2″ Garrett Vascular Dilator Set of 9 combines a 5 1/2-inch overall length with smooth tapered tips. Its defined working profile is intended for controlled vessel dilation in cardiovascular applications.

Design & Function

The Garrett Vascular Dilator features a progressive working configuration designed to provide a specialized orientation during vessel dilation. The smooth tapered tip design can assist in positioning the working end according to the requirements of the operative field.

The tapered tip profile provides a defined dilation profile, while the 5 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a progressive dilator.

Surgical Applications

The 5 1/2″ Garrett Vascular Dilator Set of 9 may be used for cardiovascular and peripheral vascular applications involving atraumatic vessel dilation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the vascular dilator before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the vascular dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Vascular Dilator?
The overall length is 5 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features smooth tapered tips.

3. Is this Vascular Dilator curved or straight?
It features a progressive configuration.

4. What is a Vascular Dilator used for?
It is designed for controlled vessel dilation in cardiovascular applications.

5. What clinical advantage does the tapered tip provide?
The tapered tip provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and peripheral vascular applications where a progressive dilator is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Vascular Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.