5 1/4″ Cooley Pediatric Clamp – 20mm (3/4″) Jaw
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33590
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-33590AISI 420 Martensitic

5 1/4″ Cooley Pediatric Clamp 20mm Jaw

4.9 / 5.0•18 Verified OR Evaluations
$399.00$422.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $23.00 (5% OFF)
  • 5 1/4″ Cooley Pediatric Clamp designed with a straight configuration for secure vessel control.
  • 20mm jaw dimension provides a defined clamping profile for pediatric procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for pediatric and cardiac surgery applications requiring a straight clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5 1/4″ Cooley Pediatric Clamp is a specialized cardiovascular instrument designed for secure vessel control in pediatric and microsurgical procedures. Its 20mm (3/4″) jaw provides a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of 5 1/4 inches and a 20mm jaw dimension, this clamp provides a defined clamping profile for pediatric applications. The ergonomic design allows the working end to approach delicate vessels from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 5 1/4-inch overall length for controlled manual handling.
  • 20mm (3/4″) jaw dimension provides a defined clamping profile.
  • Ergonomic design for specialized working orientation.
  • Designed for secure vessel control in pediatric and microsurgical procedures.
  • Suitable for pediatric cardiac and reconstructive surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Pediatric Clamp
Overall Length5 1/4″
Working End / Blade / Jaw20mm Jaw
ConfigurationStraight
Primary FunctionVessel Control
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypePediatric / Cardiac Surgery

The 5 1/4″ Cooley Pediatric Clamp combines a 5 1/4-inch overall length with a 20mm jaw dimension and straight configuration.
Its defined working profile is intended for secure vessel control in pediatric applications.

Design & Function

The Cooley Pediatric Clamp features a straight working configuration designed to provide a specialized orientation during vessel control procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 20mm jaw profile provides a defined clamping profile, while the 5 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for pediatric procedures requiring a straight instrument type.

Surgical Applications

The 5 1/4″ Cooley Pediatric Clamp may be used for pediatric and cardiac surgery applications involving secure vessel control. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Pediatric Clamp before use, paying particular attention to the jaw alignment and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Pediatric Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cooley Pediatric Clamp?
The overall length is 5 1/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features 20mm jaw.

3. Is this Cooley Pediatric Clamp curved or straight?
It features a Straight configuration.

4. What is a Cooley Pediatric Clamp used for?
It is designed for controlled vessel control in pediatric applications.

5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for pediatric surgery?
It may be used in pediatric and cardiac surgery applications where a straight clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Cooley Pediatric Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.