
5 1/2″ Gregory Femoral Artery Clamp Curved Left
Direct Manufacturer Pricing • Tax Exclusive
- 5 1/2″ Gregory Femoral Artery Clamp Curved Left designed with a curved configuration for gentle vessel occlusion.
- Curved left jaws provide a defined clamping profile for cardiovascular procedures.
- Curved design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring a curved clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5 1/2″ Gregory Femoral Artery Clamp Curved Left is a specialized cardiovascular instrument designed for femoral artery and peripheral vascular procedures requiring directional access and gentle vessel occlusion. Its left-curved jaw configuration provides a distinct working orientation that can assist with positioning the working end within the operative field.
With an overall length of 5 1/2 inches and a curved jaw design, this clamp provides a defined clamping profile for vascular applications. The atraumatic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 5 1/2-inch overall length for controlled manual handling.
- Curved left jaws improve anatomical access.
- Atraumatic design minimizes endothelial damage.
- Secure ratchet locking mechanism.
- Designed for femoral artery and peripheral vascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Gregory pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Gregory Femoral Artery Clamp |
| Overall Length | 5 1/2″ |
| Working End / Blade / Jaw | Curved left jaws |
| Configuration | Curved |
| Primary Function | Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 5 1/2″ Gregory Femoral Artery Clamp Curved Left combines a 5 1/2-inch overall length with a curved jaw design.
Its defined working profile is intended for vessel occlusion in cardiovascular applications.
Design & Function
The Gregory Femoral Artery Clamp features a curved working configuration designed to provide a specialized orientation during vascular procedures. The curved jaw design can assist in positioning the working end according to the requirements of the operative field.
The curved left jaws provide a defined clamping profile, while the 5 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a curved instrument type.
Surgical Applications
The 5 1/2″ Gregory Femoral Artery Clamp Curved Left may be used for cardiovascular and vascular surgery applications involving gentle vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Gregory Femoral Artery Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Gregory Femoral Artery Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this clamp?
The overall length is 5 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features curved left jaws.
3. Is this clamp curved or straight?
It features a curved configuration.
4. What is a Gregory Femoral Artery Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.
5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a curved clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Gregory Femoral Artery Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
