5⅜″ Meniscus Clamp Straight
Direct Manufacturer Pricing • Tax Exclusive
The 5⅜″ Straight Meniscus Clamp is a specialized orthopedic surgical instrument designed for use in appropriate procedures involving the knee meniscus. Its straight configuration provides a direct working profile for controlled instrument handling, subject to the manufacturer's specifications and intended clinical applications.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5⅜″ Meniscus Clamp Straight is a specialized orthopedic instrument intended for selected procedures involving meniscal tissue in the knee. With a stated overall length of 5⅜ inches, this instrument offers a compact profile for professional surgical environments. Its straight design distinguishes it from curved meniscus clamps and other grasping instruments with angled working ends.
Design and Configuration
The straight configuration provides a direct instrument profile that may be preferred for particular approaches to the operative field. The working-end design, jaw shape, gripping surface, and opening range determine how the clamp interacts with tissue and should be confirmed through the manufacturer's product specifications.
The stated overall length of 5⅜ inches is approximately 13.65 cm. This measurement helps distinguish the instrument from meniscus clamps of different lengths. However, overall length alone does not establish the instrument's reach, grasping capacity, or suitability for a particular procedure.
Orthopedic and Meniscal Applications
The meniscus is a fibrocartilaginous structure within the knee joint that contributes to load distribution and joint stability. Instruments intended for meniscal procedures may assist qualified orthopedic surgeons in handling tissue during selected surgical techniques.
The exact role of this straight meniscus clamp depends on its jaw design and manufacturer-defined intended use. The product title does not provide enough information to confirm whether it is designed for grasping, positioning, or another specific task. Its use should therefore follow the manufacturer's instructions and the clinical judgment of the treating surgical team.
Straight Design and Instrument Selection
Straight instruments offer a different working geometry from curved models. Depending on the surgical approach and anatomical access, a straight configuration may be considered alongside other instrument designs. The preferred model depends on the operative technique, access requirements, and the instrument's validated function.
When comparing meniscus clamps, buyers should review the jaw profile, tip dimensions, handle configuration, overall length, and closing mechanism. These details are more informative than the instrument name alone when determining suitability for a particular procedure.
Material and Construction
The exact material composition of this clamp is not specified in the product title. Reusable orthopedic instruments are commonly manufactured from medical-grade stainless steel, but the alloy, surface finish, and construction of this particular model should be verified with the supplier.
Quality construction is important for maintaining jaw alignment, reliable mechanical operation, and resistance to corrosion under approved reprocessing conditions. Professional buyers should request the manufacturer's technical specifications and applicable quality documentation before purchasing the instrument for clinical use.
Handling and Inspection
Before use, inspect the jaws for alignment, damage, corrosion, and wear. Check the handles and any pivot or closing mechanism for smooth operation. The clamp should function according to the manufacturer's specifications and should not be used if the working end is damaged or closes irregularly.
Use the instrument only for its approved purpose and according to the surgical team's established procedures. Proper handling and routine inspection help identify defects before the instrument enters clinical service.
Cleaning and Sterilization
Cleaning and sterilization must follow the manufacturer's validated instructions and the healthcare facility's approved reprocessing procedures. Pay particular attention to the jaw surfaces, pivot, and any joints where biological material may accumulate.
After cleaning, inspect the instrument for residual contamination, corrosion, and mechanical defects before sterilization. Confirm whether the model is reusable and which sterilization methods are approved for its materials and construction.
Selecting the Appropriate Meniscus Clamp
When purchasing the 5⅜″ Straight Meniscus Clamp, verify the overall length, jaw configuration, tip dimensions, handle design, material composition, and intended clinical application. Comparing these specifications with those of curved or differently sized meniscus clamps helps ensure accurate instrument selection.
For orthopedic departments, hospitals, and professional surgical instrument suppliers, manufacturer verification is essential to confirm that the selected instrument meets the requirements of its intended surgical environment.
Key Features
Straight meniscus clamp configuration
Stated overall length of 5⅜ inches
Metric length of approximately 13.65 cm
Designed for evaluation for selected meniscal procedures
Straight working profile
Jaw shape and gripping characteristics to be confirmed
Material composition to be verified with the manufacturer
Inspect jaws and mechanical components before use
Use according to manufacturer instructions and approved clinical indications
Cleaning and sterilization according to validated reprocessing instructions
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Meniscus Clamp Straight |
| Overall Length | 5⅜ inches |
| Metric Length | Approximately 13.65 cm |
| Instrument Type | Orthopedic clamp |
| Design | Straight |
| Intended Application | Selected meniscal procedures, subject to manufacturer indications |
| Jaw Configuration | Confirm with manufacturer |
| Tip Dimensions | Confirm with manufacturer |
| Material | Confirm with manufacturer |
| Closing Mechanism | Confirm with manufacturer |
| Sterilization | Follow validated manufacturer instructions |
| Reusable Status | Confirm with manufacturer |
Frequently Asked Questions
1. What is a 5⅜″ Straight Meniscus Clamp used for?
It is a specialized orthopedic instrument associated with procedures involving the knee meniscus. Its precise function should be confirmed through the manufacturer's intended-use documentation.
2. What is the overall length of this meniscus clamp?
The stated overall length is 5⅜ inches, approximately 13.65 cm.
3. What is the difference between straight and curved meniscus clamps?
The primary difference is the working-end geometry. Straight and curved designs offer different approach profiles, and selection depends on the surgical technique and manufacturer's specifications.
4. What material is this meniscus clamp made from?
The product title does not specify the material. Confirm the alloy and surface finish with the manufacturer or supplier.
5. Is this clamp suitable for all meniscal procedures?
No single instrument should be assumed suitable for every procedure. Its use depends on the instrument's design, approved indications, and the surgeon's clinical judgment.
6. How should a reusable meniscus clamp be sterilized?
Follow the manufacturer's validated cleaning and sterilization instructions and the healthcare facility's approved reprocessing procedures.
7. What should I inspect before using this instrument?
Check jaw alignment, surface condition, corrosion, handle integrity, and the operation of any pivot or closing mechanism.
8. What should buyers verify before ordering?
Confirm the 5⅜-inch length, straight configuration, jaw and tip dimensions, intended application, material composition, and reprocessing requirements.