55mm Image-Line blade – long teeth black Standard Blade
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-53029
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-53029AISI 420 Martensitic

55mm Image-Line Blade Long Teeth Black Standard Blade

4.9 / 5.0•18 Verified OR Evaluations
$229.00$249.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (8% OFF)
  • 55mm Image-Line Blade Long Teeth Black Standard Blade designed with a standard configuration for firm tissue engagement.
  • Long teeth design provides a defined engagement profile for microsurgical procedures.
  • Standard design supports a specialized working orientation within the operative field.
  • Suitable for microsurgical and spinal surgery applications requiring a standard retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 55mm Image-Line Blade Long Teeth Black Standard Blade is a specialized microsurgical instrument designed for firm tissue engagement in spinal procedures. Its long teeth provide a distinct working orientation that can assist with positioning the blade within the operative field.

With an overall length of 55mm and a standard blade attachment, this retractor provides a defined engagement profile for microsurgical applications. The ergonomic design allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 55mm overall length for balanced access and controlled handling.
  • Long teeth design provides a secure tissue purchase.
  • Standard blade configuration for versatile applications.
  • Designed for firm tissue engagement in microsurgical and spinal procedures.
  • Suitable for a variety of surgical applications requiring precision and reliability.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeImage-Line Blade
Overall Length55mm
Working End / Blade / JawLong teeth design
ConfigurationStandard
Primary FunctionTissue Engagement
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeMicrosurgical / Spinal Surgery

The 55mm Image-Line Blade Long Teeth Black Standard Blade combines a 55mm overall length with a long teeth design and standard configuration.
Its defined working profile is intended for firm tissue engagement in microsurgical applications.

Design & Function

The Image-Line Blade features a standard working configuration designed to provide a specialized orientation during tissue engagement. The long teeth design can assist in positioning the blade according to the requirements of the operative field.

The long teeth profile provides a defined engagement profile, while the 55mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for microsurgical procedures requiring a standard retractor.

Surgical Applications

The 55mm Image-Line Blade Long Teeth Black Standard Blade may be used for microsurgical and spinal surgery applications involving firm tissue engagement. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Image-Line Blade before use, paying particular attention to the working end and teeth alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Image-Line Blade appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Image-Line Blade?
The overall length is 55mm.

2. What is the working end / blade design of the instrument?
It features long teeth design.

3. Is this Image-Line Blade curved or straight?
It features a standard configuration.

4. What is an Image-Line Blade used for?
It is designed for controlled tissue engagement in microsurgical applications.

5. What clinical advantage does the long teeth design provide?
The long teeth provide a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in microsurgical and spinal surgery applications where a standard retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Image-Line Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.