55mm Image-Line blade – long teeth black
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-52335
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-52335AISI 420 Martensitic

55mm Image-Line Blade Long Teeth Black

4.9 / 5.0•18 Verified OR Evaluations
$229.00$249.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (8% OFF)
  • 55mm Image-Line Blade Long Teeth Black designed with a straight configuration for effective tissue retraction.
  • Long teeth design provides a defined retraction profile for spinal procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for spinal and neurosurgery applications requiring a retractor.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 55mm Image-Line Blade Long Teeth Black is a specialized retractor designed for effective tissue engagement and retraction in mid-to-deep spinal operative fields. Its long teeth provide a strong grip, ensuring efficient separation and exposure during surgical procedures.

With an overall length of 55mm, this retractor offers an extended reach, allowing surgeons to access deeper anatomical structures with ease. The black color-coded design enhances visibility and identification within the surgical field, supporting precise manual manipulation during operations.

Key Features

  • 55mm overall length for extended reach in surgical applications.
  • Long teeth design provides a strong tissue grip for effective retraction.
  • Black color-coded configuration enhances visibility and identification.
  • Designed for efficient tissue engagement and exposure.
  • Suitable for spinal surgery applications requiring deep access.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeImage-Line Blade
Overall Length55mm
Working End / Blade / JawLong Teeth
ConfigurationBlack
Primary FunctionTissue Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeSpinal Surgery

The 55mm Image-Line Blade Long Teeth Black combines a 55mm overall length with long teeth design.
Its defined working profile is intended for effective tissue retraction in spinal surgery applications.

Design & Function

The Image-Line Blade features a long teeth configuration designed to provide a specialized orientation during spinal procedures. The long teeth can assist in positioning the working end according to the requirements of the operative field.

The long teeth provide a defined retraction profile, while the 55mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a retractor.

Surgical Applications

The 55mm Image-Line Blade Long Teeth Black may be used for spinal and neurosurgery applications involving tissue retraction and exposure. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Image-Line Blade before use, paying particular attention to the working end and teeth alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Image-Line Blade appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Image-Line Blade?
The overall length is 55mm.

2. What is the working end / blade design of the instrument?
It features long teeth.

3. Is this Image-Line Blade curved or straight?
It features a straight configuration.

4. What is an Image-Line Blade used for?
It is designed for controlled tissue retraction in spinal surgery applications.

5. What clinical advantage does the long teeth provide?
The long teeth provide a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal and neurosurgery applications where a retractor is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Image-Line Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.