5mm Safety Locking Screws Self Tapping Titanium
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-79896
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
MaxillofacialSKU: SP-79896AISI 420 Martensitic

5mm Safety Locking Screws Self Tapping Titanium

4.9 / 5.0•18 Verified OR Evaluations
$350.00$400.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $50.00 (13% OFF)

5mm Titanium Self-Tapping Safety Locking Screws are orthopedic fixation components designed for use with compatible locking plate systems. Their self-tapping design supports screw insertion into prepared bone according to the applicable surgical technique. Confirm the screw length, thread specifications, titanium grade, and plate compatibility with the manufacturer before ordering.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

5mm Titanium Self-Tapping Safety Locking Screws are specialized orthopedic implant components intended for compatible bone fixation systems. Locking screws are designed to engage with matching threaded plate holes, creating a fixed-angle connection between the screw and plate when used within a compatible system.

The 5mm specification identifies the listed screw diameter, but the complete dimensions and technical details should be verified with the supplier. Correct screw selection depends on the anatomical application, plate system, bone characteristics, and requirements of the planned fixation procedure.

Self-Tapping Screw Design

The self-tapping feature is intended to help the screw form its mating thread during insertion into bone, subject to the manufacturer's specified surgical technique. Depending on the implant design and bone conditions, the manufacturer may specify whether pre-drilling, tapping, or other preparation is required.

Self-tapping characteristics can vary between screw systems. Surgeons should follow the applicable surgical technique guide and use compatible instruments rather than assuming that every self-tapping screw has identical insertion requirements.

Locking Mechanism and Plate Compatibility

Locking screws are designed to work with matching locking holes in compatible plates. The threaded interface helps establish the intended screw-to-plate connection, which differs from conventional screws that rely primarily on compression between the plate and bone.

Compatibility is system-specific. The screw diameter alone does not establish whether a screw will fit a particular plate. Confirm the manufacturer's system, thread geometry, screw head design, length, and approved plate combinations before use.

Titanium Material

The product title identifies titanium as the material. However, it does not specify the exact titanium grade, alloy, surface finish, or applicable material standard. These details should be confirmed through the manufacturer's technical documentation.

Titanium alloys are commonly used in orthopedic implants because of their favorable strength-to-weight characteristics and suitability for certain implant applications. The properties of this particular screw depend on its verified material composition and manufacturing specifications.

Orthopedic Applications

Locking screws are used in compatible orthopedic fixation constructs to secure plates to bone. The appropriate screw design and dimensions depend on the specific implant system and clinical indication. This product should only be selected for applications approved by the manufacturer and assessed as appropriate by the treating surgeon.

The word “safety” in the product name should not be interpreted as a guarantee of clinical outcomes or universal compatibility. Verify the product's official designation and intended use before listing or purchasing it.

Selection and Technical Verification

Before ordering, confirm the nominal diameter, available screw lengths, thread pitch and profile, head design, drive type, titanium grade, and compatibility with the intended locking plate system. Also verify whether the screw is supplied sterile or non-sterile and review its single-use status, packaging, traceability, and regulatory documentation.

Use only the instruments and insertion technique specified by the manufacturer. Proper product identification and system compatibility are essential when selecting orthopedic implant components.

Key Features

  • Orthopedic locking screw with a listed 5mm diameter

  • Self-tapping design as specified in the product name

  • Titanium material, with exact grade to be confirmed

  • Intended for compatible locking plate fixation systems

  • Designed for a matching screw-to-plate threaded interface

  • Screw length must be selected for the specific application

  • Plate compatibility depends on the manufacturer's system

  • Thread profile and head design require verification

  • Sterile status and packaging details should be confirmed

  • Follow the manufacturer's approved surgical technique and implant instructions

Product Specifications

SpecificationDetails
Product NameTitanium Self-Tapping Safety Locking Screw
Screw Diameter5mm, as listed
Screw TypeLocking screw
Thread DesignSelf-tapping, as listed
MaterialTitanium; exact grade to be confirmed
Screw LengthNot specified
Head DesignConfirm with manufacturer
Drive TypeNot specified
Thread ProfileConfirm with manufacturer
CompatibilityMatching approved locking plate system
Sterile StatusConfirm product packaging and labeling
Intended UseOrthopedic bone fixation, subject to manufacturer indications
Regulatory DocumentationConfirm with supplier

Frequently Asked Questions

1. What is a 5mm titanium self-tapping locking screw used for?

It is an orthopedic implant component intended for use with compatible locking plate systems. The specific clinical application depends on the implant system and manufacturer instructions.

2. What does 5mm refer to?

The product title indicates a 5mm screw diameter. Confirm the manufacturer's dimensional specification before selecting the screw.

3. What does self-tapping mean?

A self-tapping screw is designed to form its mating thread during insertion under the specified conditions. Follow the manufacturer's guidance regarding drilling, tapping, and insertion technique.

4. What is the purpose of the locking feature?

The locking feature allows the screw head to engage with a matching threaded plate hole, creating a fixed-angle screw-to-plate connection in a compatible system.

5. Are these screws compatible with every 5mm locking plate?

No. Matching diameter alone does not guarantee compatibility. The thread geometry, head design, and plate system must also match the manufacturer's specifications.

6. What type of titanium is used?

The product title does not identify the exact titanium grade or alloy. Request the material specification and supporting documentation from the supplier.

7. What screw lengths are available?

The screw length is not provided in the title. Check the supplier's available size options and select a length approved for the intended fixation system.

8. Are these screws supplied sterile?

Sterile status is not specified. Check the product labeling, packaging, and manufacturer's instructions before clinical use.

9. Can these screws be reused?

Implant screws are generally intended for single use, but the status of this specific product must be confirmed through its official labeling. Do not reuse an implant unless the manufacturer and applicable regulations explicitly permit it.