5″ Cooley Coronary Dilator – aluminum 1.5mm shaft
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-34310
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-34310AISI 420 Martensitic

5″ Cooley Coronary Dilator 1.5mm Aluminum

4.9 / 5.0•18 Verified OR Evaluations
$68.00$99.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $31.00 (31% OFF)
  • 5″ Cooley Coronary Dilator designed with a straight configuration for atraumatic dilation of coronary vessels.
  • 1.5 mm shaft diameter provides a defined dilation profile for cardiovascular procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and cardiac surgery applications requiring a straight Coronary Dilator.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5″ Cooley Coronary Dilator is a specialized cardiovascular instrument designed for atraumatic dilation of coronary vessels during delicate cardiac procedures. Its 1.5 mm aluminum shaft provides a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 5 inches and a 1.5 mm shaft diameter, this Coronary Dilator provides a defined dilation profile for cardiovascular applications. The lightweight design allows the working end to approach coronary vessels from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 5-inch overall length for controlled manual handling.
  • 1.5 mm shaft diameter provides a defined dilation profile.
  • Lightweight configuration for specialized working orientation.
  • Designed for atraumatic dilation of coronary vessels.
  • Suitable for cardiovascular and cardiac surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade aluminum construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Coronary Dilator
Overall Length5″
Working End / Blade / Jaw1.5 mm shaft diameter
ConfigurationStraight
Primary FunctionAtraumatic Dilation
MaterialAluminum
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Cardiac Surgery

The 5″ Cooley Coronary Dilator combines a 5-inch overall length with a 1.5 mm shaft diameter and Straight configuration.
Its defined working profile is intended for atraumatic dilation in cardiovascular applications.

Design & Function

The Cooley Coronary Dilator features a straight working configuration designed to provide a specialized orientation during cardiac procedures. The aluminum shaft can assist in positioning the working end according to the requirements of the operative field.

The 1.5 mm shaft diameter provides a defined dilation profile, while the 5-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a straight instrument type.

Surgical Applications

The 5″ Cooley Coronary Dilator may be used for cardiovascular and cardiac surgery applications involving atraumatic dilation of coronary vessels. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Coronary Dilator before use, paying particular attention to the working end and shaft alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Coronary Dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Coronary Dilator?
The overall length is 5 inches.

2. What is the working end / blade or tip design of the instrument?
It features 1.5 mm shaft diameter.

3. Is this Coronary Dilator curved or straight?
It features a Straight configuration.

4. What is a Coronary Dilator used for?
It is designed for controlled atraumatic dilation in cardiovascular applications.

5. What clinical advantage does the lightweight design provide?
The lightweight design provides enhanced maneuverability and reduces hand fatigue.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and cardiac surgery applications where a straight and lightweight Coronary Dilator is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Coronary Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.