5″ Cooley Neonatal Vascular Clamp – angled shanks straight
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-32826
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-32826AISI 420 Martensitic

5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight

4.9 / 5.0•18 Verified OR Evaluations
$385.00$409.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $24.00 (6% OFF)
  • 5″ Cooley Neonatal Vascular Clamp designed with an angled configuration for gentle vascular clamping.
  • Straight jaw design provides a defined clamping profile for neonatal procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for neonatal and pediatric vascular surgery applications requiring an angled vascular clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5″ Cooley Neonatal Vascular Clamp is a specialized cardiovascular instrument designed for neonatal and pediatric vascular surgery, where vessel fragility demands gentle, reliable control. Its angled shanks with straight jaws provide a distinct working orientation that can assist with positioning the jaws within the operative field.

With an overall length of 5 inches and a straight jaw design, this vascular clamp provides a defined clamping profile for neonatal applications. The angled configuration allows the working end to approach delicate vessels from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 5-inch overall length for controlled manual handling.
  • Straight jaw design provides a defined clamping profile.
  • Angled configuration for specialized working orientation.
  • Designed for gentle vascular control during surgery.
  • Suitable for neonatal and pediatric vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Neonatal Vascular Clamp
Overall Length5″
Working End / Blade / JawStraight jaws
ConfigurationAngled
Primary FunctionVascular Clamping
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeonatal / Pediatric Surgery

The 5″ Cooley Neonatal Vascular Clamp combines a 5-inch overall length with straight jaws and an angled configuration.
Its defined clamping profile is intended for gentle vascular control in neonatal applications.

Design & Function

The Cooley Neonatal Vascular Clamp features an angled working configuration designed to provide a specialized orientation during vascular procedures. The straight jaw design can assist in positioning the working end according to the requirements of the operative field.

The jaw profile provides a defined clamping profile, while the 5-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neonatal procedures requiring an angled vascular clamp.

Surgical Applications

The 5″ Cooley Neonatal Vascular Clamp may be used for neonatal and pediatric vascular surgery applications involving gentle vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the vascular clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the vascular clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Vascular Clamp?
The overall length is 5 inches.

2. What is the working end / blade or tip design of the instrument?
It features straight jaws.

3. Is this Vascular Clamp curved or straight?
It features an angled configuration.

4. What is a Vascular Clamp used for?
It is designed for controlled vascular clamping in neonatal applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neonatal surgery?
It may be used in neonatal and pediatric surgery applications where an angled vascular clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Vascular Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.