5″ Neonatal Vascular Clamp – jaws 90 ° curved shanks
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33108
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-33108AISI 420 Martensitic

5″ Neonatal Vascular Clamp 90° Curved

4.9 / 5.0•18 Verified OR Evaluations
$322.00$344.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $22.00 (6% OFF)
  • 5″ Neonatal Vascular Clamp designed with a curved configuration for precise vessel occlusion.
  • 90° curved jaws provide a defined clamping profile for cardiovascular procedures.
  • Curved design supports a specialized working orientation within the operative field.
  • Suitable for pediatric and cardiovascular applications requiring a curved clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5″ Neonatal Vascular Clamp is a specialized cardiovascular instrument designed for precise occlusion of small vessels in neonatal and pediatric surgeries. Its 90° curved jaws provide excellent access to delicate vessels in confined surgical fields, while the atraumatic design minimizes vessel trauma.

With an overall length of 5 inches and a 90° jaw curvature, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach delicate vessels from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 5-inch overall length for controlled manual handling.
  • 90° jaw curvature provides a defined clamping profile.
  • Curved configuration for specialized working orientation.
  • Designed for precise occlusion of small vessels.
  • Suitable for cardiovascular, thoracic, and microvascular applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Neonatal pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeNeonatal Vascular Clamp
Overall Length5″
Working End / Blade / Jaw90° Curved Jaws
ConfigurationCurved
Primary FunctionVessel Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Pediatric Surgery

The 5″ Neonatal Vascular Clamp combines a 5-inch overall length with 90° curved jaws.
Its defined working profile is intended for precise occlusion of small vessels in cardiovascular applications.

Design & Function

The Neonatal Vascular Clamp features a curved working configuration designed to provide a specialized orientation during vessel occlusion. The 90° jaw design can assist in positioning the working end according to the requirements of the operative field.

The jaw profile provides a defined clamping profile, while the 5-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for pediatric procedures requiring a curved instrument type.

Surgical Applications

The 5″ Neonatal Vascular Clamp may be used for cardiovascular and pediatric surgery applications involving precise occlusion of small vessels. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Neonatal Vascular Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Neonatal Vascular Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Neonatal Vascular Clamp?
The overall length is 5 inches.

2. What is the working end / blade or tip design of the instrument?
It features 90° curved jaws.

3. Is this Neonatal Vascular Clamp curved or straight?
It features a curved configuration.

4. What is a Neonatal Vascular Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.

5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for pediatric surgery?
It may be used in cardiovascular and pediatric applications where a curved clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Neonatal Vascular Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.