6″ Bayonet Kerrison Rongeur – 4mm – Pin Ejector – Spurling Handle – Panther
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-49497
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-49497AISI 420 Martensitic

6″ Bayonet Kerrison Rongeur 4mm Pin Ejector Spurling Handle

4.9 / 5.0•18 Verified OR Evaluations
$1500.00$1600.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $100.00 (6% OFF)
  • 6″ Bayonet Kerrison Rongeur designed with a bayonet configuration for efficient bone removal.
  • 4 mm biting tip provides a defined cutting profile for neurosurgical procedures.
  • Bayonet design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal surgery applications requiring a bayonet rongeur.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6″ Bayonet Kerrison Rongeur is a specialized neurosurgical instrument designed for efficient bone removal in spinal and neurosurgical procedures where visibility and control are critical. Its bayonet-style shaft keeps the surgeon’s hand out of the operative line of sight, improving visualization in deep or narrow surgical fields.

With an overall length of 6 inches and a 4 mm biting tip, this rongeur provides a defined cutting profile for neurosurgical applications. The integrated pin ejector mechanism ensures smooth removal of bone fragments, maintaining a clear operative field during procedures.

Key Features

  • 6-inch overall length for optimal maneuverability.
  • 4 mm biting tip provides a defined cutting profile.
  • Bayonet configuration for improved visibility and control.
  • Designed for efficient bone removal in spinal and neurosurgical procedures.
  • Suitable for neurosurgical applications requiring precision and clarity.
  • Supports positioning of the working end within the operative field.
  • Specialized Spurling handle for enhanced grip and control.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeBayonet Kerrison Rongeur
Overall Length6″
Working End / Blade / Jaw4 mm biting tip
ConfigurationBayonet
Primary FunctionBone Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 6″ Bayonet Kerrison Rongeur combines a 6-inch overall length with a 4 mm biting tip and bayonet configuration.
Its defined working profile is intended for efficient bone removal in neurosurgical applications.

Design & Function

The Bayonet Kerrison Rongeur features a bayonet working configuration designed to provide a specialized orientation during spinal procedures. The 4 mm biting tip can assist in positioning the working end according to the requirements of the operative field.

The 4 mm biting tip provides a defined cutting profile, while the 6-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a bayonet instrument type.

Surgical Applications

The 6″ Bayonet Kerrison Rongeur may be used for neurosurgical and spinal surgery applications involving efficient bone removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Bayonet Kerrison Rongeur?
The overall length is 6 inches.

2. What is the working end / blade or tip design of the instrument?
It features 4 mm biting tip.

3. Is this Bayonet Kerrison Rongeur curved or straight?
It features a bayonet configuration.

4. What is a Bayonet Kerrison Rongeur used for?
It is designed for controlled bone removal in neurosurgical applications.

5. What clinical advantage does the bayonet design provide?
The bayonet design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal surgery applications where a bayonet and 4 mm rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Bayonet Kerrison Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.