6″ Debakey Peripheral Vascular Clamp Curved Jaws
Direct Manufacturer Pricing • Tax Exclusive
- 6″ Debakey Peripheral Vascular Clamp Curved Jaws designed with a curved configuration for atraumatic vessel occlusion.
- Curved jaw design provides a defined clamping profile for cardiovascular procedures.
- Curved design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring a curved instrument type.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6″ Debakey Peripheral Vascular Clamp Curved Jaws is a specialized cardiovascular instrument designed for atraumatic occlusion of peripheral vessels during vascular and reconstructive procedures. Its curved jaws provide improved access and secure vessel control, while Debakey teeth ensure a firm yet gentle grip within the operative field.
With an overall length of 6 inches and a curved jaw design, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 6-inch overall length for controlled manual handling.
- Curved jaw design provides a defined clamping profile.
- Curved configuration for specialized working orientation.
- Designed for atraumatic occlusion of peripheral vessels.
- Suitable for cardiovascular and vascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Debakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Debakey Peripheral Vascular Clamp |
| Overall Length | 6″ |
| Working End / Blade / Jaw | Curved jaws |
| Configuration | Curved |
| Primary Function | Atraumatic Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 6″ Debakey Peripheral Vascular Clamp Curved Jaws combines a 6-inch overall length with a curved jaw design.
Its defined working profile is intended for atraumatic occlusion of peripheral vessels in cardiovascular applications.
Design & Function
The Debakey Peripheral Vascular Clamp features a curved working configuration designed to provide a specialized orientation during vascular procedures. The curved jaw design can assist in positioning the working end according to the requirements of the operative field.
The curved jaw profile provides a defined clamping profile, while the 6-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a curved instrument type.
Surgical Applications
The 6″ Debakey Peripheral Vascular Clamp Curved Jaws may be used for cardiovascular and vascular surgery applications involving atraumatic occlusion of peripheral vessels. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Debakey Peripheral Vascular Clamp before use, paying particular attention to the working end, jaw alignment, and gripping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Peripheral Vascular Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Debakey Peripheral Vascular Clamp?
The overall length is 6 inches.
2. What is the working end / blade or tip design of the instrument?
It features curved jaws.
3. Is this Debakey Peripheral Vascular Clamp curved or straight?
It features a curved configuration.
4. What is a Debakey Peripheral Vascular Clamp used for?
It is designed for controlled atraumatic vessel occlusion in cardiovascular applications.
5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a curved instrument type is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Debakey Peripheral Vascular Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.