
6 1/2″ Debakey Derra Anastomosis Clamp Small Jaw
Direct Manufacturer Pricing • Tax Exclusive
- 6 1/2″ Debakey Derra Anastomosis Clamp Small Jaw designed with an atraumatic configuration for precise vessel approximation and anastomosis.
- Small jaw dimension provides a defined clamping profile for cardiovascular procedures.
- Atraumatic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and microvascular surgery applications requiring an atraumatic clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6 1/2″ Debakey Derra Anastomosis Clamp Small Jaw is a specialized cardiovascular instrument designed for precise vessel approximation in delicate microvascular and cardiovascular procedures. Its fine, atraumatic jaws provide a secure grip without damaging vessel walls, allowing surgeons to perform accurate anastomoses with confidence.
With an overall length of 6 1/2 inches and small jaw dimensions, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 6 1/2-inch overall length for controlled manual handling.
- Small jaw dimension provides a defined clamping profile.
- Atraumatic configuration for specialized working orientation.
- Designed for precise vessel approximation and anastomosis.
- Suitable for cardiovascular and microvascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Debakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Debakey Derra Anastomosis Clamp |
| Overall Length | 6 1/2″ |
| Working End / Blade / Jaw | Small jaw |
| Configuration | Atraumatic |
| Primary Function | Vessel Approximation and Anastomosis |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Microvascular Surgery |
The 6 1/2″ Debakey Derra Anastomosis Clamp Small Jaw combines a 6 1/2-inch overall length with small jaw dimensions and atraumatic configuration.
Its defined working profile is intended for precise vessel approximation and anastomosis in cardiovascular applications.
Design & Function
The Debakey Derra Anastomosis Clamp features an atraumatic working configuration designed to provide a specialized orientation during vessel approximation. The small jaw design can assist in positioning the working end according to the requirements of the operative field.
The small jaw profile provides a defined clamping profile, while the 6 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an atraumatic instrument type.
Surgical Applications
The 6 1/2″ Debakey Derra Anastomosis Clamp Small Jaw may be used for cardiovascular and microvascular surgery applications involving vessel approximation and anastomosis. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Debakey Derra Anastomosis Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Derra Anastomosis Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Debakey Derra Anastomosis Clamp?
The overall length is 6 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features small jaw.
3. Is this Debakey Derra Anastomosis Clamp curved or straight?
It features an atraumatic configuration.
4. What is a Debakey Derra Anastomosis Clamp used for?
It is designed for controlled vessel approximation and anastomosis in cardiovascular applications.
5. What clinical advantage does the atraumatic design provide?
The atraumatic design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and microvascular surgery applications where an atraumatic and small jaw clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Debakey Derra Anastomosis Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
