6 1/2″ Cooley Anastomosis Clamp – Calibrated Jaw
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-31276
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-31276AISI 420 Martensitic

6 1/2″ Cooley Anastomosis Clamp Calibrated Jaw

4.9 / 5.0•18 Verified OR Evaluations
$285.00$305.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (7% OFF)
  • 6 1/2″ Cooley Anastomosis Clamp Calibrated Jaw designed with a calibrated configuration for controlled vessel occlusion.
  • Calibrated jaw design provides a defined clamping profile for cardiovascular procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a calibrated clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 1/2″ Cooley Anastomosis Clamp Calibrated Jaw is a specialized cardiovascular instrument designed for controlled vessel occlusion during anastomotic procedures. Its calibrated jaw design allows surgeons to apply consistent and controlled pressure across the vessel, ensuring uniform occlusion while maintaining vessel shape.

With an overall length of 6 1/2 inches and a calibrated jaw profile, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach the vessel from a specialized angle, supporting precision alignment and reducing the risk of vessel damage during suturing.

Key Features

  • 6 1/2-inch overall length for controlled manual handling.
  • Calibrated jaw design provides a defined clamping profile.
  • Ergonomic design for specialized working orientation.
  • Designed for controlled vessel occlusion during anastomotic procedures.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports precision alignment and reduces the risk of vessel damage.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Anastomosis Clamp
Overall Length6 1/2″
Working End / Blade / JawCalibrated Jaw
ConfigurationCalibrated
Primary FunctionVessel Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 6 1/2″ Cooley Anastomosis Clamp Calibrated Jaw combines a 6 1/2-inch overall length with a calibrated jaw profile. Its defined working profile is intended for controlled vessel occlusion in cardiovascular applications.

Design & Function

The Cooley Anastomosis Clamp features a calibrated working configuration designed to provide a specialized orientation during vessel occlusion. The calibrated jaw design can assist in positioning the working end according to the requirements of the operative field.

The calibrated jaw profile provides a defined clamping profile, while the 6 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a calibrated instrument type.

Surgical Applications

The 6 1/2″ Cooley Anastomosis Clamp Calibrated Jaw may be used for cardiovascular and vascular surgery applications involving vessel occlusion and anastomosis. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Anastomosis Clamp before use, paying particular attention to the calibrated jaw alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Anastomosis Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cooley Anastomosis Clamp?
The overall length is 6 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features calibrated jaw design.

3. Is this Cooley Anastomosis Clamp curved or straight?
It features a calibrated configuration.

4. What is a Cooley Anastomosis Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.

5. What clinical advantage does the calibrated jaw provide?
The calibrated jaw provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a calibrated clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Cooley Anastomosis Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.