6 1/2″ Debakey Derra Anastomosis Clamp – medium jaw
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33241
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-33241AISI 420 Martensitic

6 1/2″ DeBakey Derra Anastomosis Clamp Medium Jaw

4.9 / 5.0•18 Verified OR Evaluations
$238.00$279.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $41.00 (15% OFF)
  • 6 1/2″ DeBakey Derra Anastomosis Clamp Medium Jaw designed with a straight configuration for precise occlusion during vascular anastomosis.
  • Medium jaw dimension provides a defined clamping profile for cardiovascular procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a straight clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 1/2″ DeBakey Derra Anastomosis Clamp Medium Jaw is a specialized cardiovascular instrument designed for precise occlusion during aortic and vascular anastomosis procedures. Its medium-sized jaws offer a secure grip without damaging the vessel, making it ideal for controlled clamping in both superficial and deep surgical sites.

With an overall length of 6 1/2 inches and a medium jaw dimension, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic handle ensures optimal control, supporting manual manipulation during procedures.

Key Features

  • 6 1/2-inch overall length for controlled manual handling.
  • Medium jaw dimension provides a defined clamping profile.
  • Ergonomic design for specialized working orientation.
  • Designed for precise occlusion during vascular anastomosis.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized DeBakey pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeDeBakey Derra Anastomosis Clamp
Overall Length6 1/2″
Working End / Blade / JawMedium Jaw
ConfigurationStraight
Primary FunctionOcclusion during Vascular Anastomosis
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 6 1/2″ DeBakey Derra Anastomosis Clamp Medium Jaw combines a 6 1/2-inch overall length with a medium jaw dimension and straight configuration.
Its defined working profile is intended for precise occlusion during vascular anastomosis in cardiovascular applications.

Design & Function

The DeBakey Derra Anastomosis Clamp features a straight working configuration designed to provide a specialized orientation during vascular procedures. The medium jaw design can assist in positioning the working end according to the requirements of the operative field.

The medium jaw profile provides a defined clamping profile, while the 6 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a straight instrument type.

Surgical Applications

The 6 1/2″ DeBakey Derra Anastomosis Clamp Medium Jaw may be used for cardiovascular and vascular surgery applications involving precise occlusion during anastomosis. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the DeBakey Derra Anastomosis Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Derra Anastomosis Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Clamp?
The overall length is 6 1/2 inches.

2. What is the working end / jaw design of the instrument?
It features medium jaw.

3. Is this Clamp curved or straight?
It features a straight configuration.

4. What is a DeBakey Derra Anastomosis Clamp used for?
It is designed for controlled occlusion during vascular anastomosis in cardiovascular applications.

5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides optimal control for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a straight medium jaw clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the DeBakey Derra Anastomosis Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.