6 3/4″ Trusler Dean Dissector Scissors serrated bottom blade
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-66753
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-66753AISI 420 Martensitic

6 3/4″ Trusler-Dean Dissector Scissors Serrated Bottom Blade

4.9 / 5.0•18 Verified OR Evaluations
$265.00$280.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $15.00 (5% OFF)
  • 6 3/4″ Trusler-Dean Dissector Scissors Serrated Bottom Blade designed with a serrated configuration for delicate tissue dissection and controlled cutting.
  • Serrated bottom blade provides a defined cutting profile for plastic and reconstructive procedures.
  • Serrated design supports a specialized working orientation within the operative field.
  • Suitable for plastic and reconstructive surgery applications requiring a serrated dissection scissors.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 3/4″ Trusler-Dean Dissector Scissors Serrated Bottom Blade is a specialized surgical instrument designed for delicate tissue dissection and controlled cutting in plastic, reconstructive, and general surgical procedures. Its serrated bottom blade provides a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of 6 3/4 inches and a serrated blade design, this dissection scissors provides a defined cutting profile for surgical applications. The ergonomic design allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 6 3/4-inch overall length for controlled manual handling.
  • Serrated bottom blade provides a defined cutting profile.
  • Serrated configuration for specialized working orientation.
  • Designed for delicate tissue dissection and controlled cutting.
  • Suitable for plastic, reconstructive, and general surgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Trusler-Dean pattern for professional surgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeTrusler-Dean Dissector Scissors
Overall Length6 3/4″
Working End / Blade / JawSerrated bottom blade
ConfigurationSerrated
Primary FunctionDelicate Tissue Dissection
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypePlastic / Reconstructive Surgery

The 6 3/4″ Trusler-Dean Dissector Scissors Serrated Bottom Blade combines a 6 3/4-inch overall length with a serrated bottom blade design. Its defined working profile is intended for delicate tissue dissection in plastic and reconstructive surgical applications.

Design & Function

The Trusler-Dean Dissector Scissors features a serrated working configuration designed to provide a specialized orientation during tissue dissection. The serrated blade design can assist in positioning the cutting end according to the requirements of the operative field.

The serrated blade profile provides a defined cutting profile, while the 6 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for plastic and reconstructive procedures requiring a serrated dissection scissors.

Surgical Applications

The 6 3/4″ Trusler-Dean Dissector Scissors Serrated Bottom Blade may be used for plastic and reconstructive surgery applications involving delicate tissue dissection. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the dissection scissors before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the dissection scissors appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Dissector Scissors?
The overall length is 6 3/4 inches.

2. What is the working end / blade design of the instrument?
It features serrated bottom blade.

3. Is this Dissector Scissors curved or straight?
It features a serrated configuration.

4. What is a Dissector Scissors used for?
It is designed for controlled delicate tissue dissection in plastic and reconstructive applications.

5. What clinical advantage does the serrated design provide?
The serrated design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for plastic surgery?
It may be used in plastic and reconstructive surgery applications where a serrated dissection scissors is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Dissector Scissors be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.