6 3/4″ Micro-Pituitary Rongeur – 2mm – Panther Up
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-49248
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-49248AISI 420 Martensitic

6 3/4″ Micro-Pituitary Rongeur 2mm Panther Up

4.9 / 5.0•18 Verified OR Evaluations
$800.00$1050.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $250.00 (24% OFF)
  • 6 3/4″ Micro-Pituitary Rongeur 2mm Panther Up designed with an upward-biting configuration for delicate bone and soft tissue removal.
  • 2 mm tip size provides a defined cutting profile for neurosurgical procedures.
  • Upward-biting design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and pituitary surgery applications requiring a specialized rongeur.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 3/4″ Micro-Pituitary Rongeur 2mm Panther Up is a specialized neurosurgical instrument designed for delicate bone and soft tissue removal. Its 2mm upward-biting tip provides a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of 6 3/4 inches and a 2 mm tip size, this rongeur provides a defined cutting profile for neurosurgical applications. The upward-biting design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 6 3/4-inch overall length for controlled manual handling.
  • 2 mm tip size provides a defined cutting profile.
  • Upward-biting configuration for specialized working orientation.
  • Designed for delicate bone and soft tissue removal.
  • Suitable for neurosurgical and pituitary surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Panther Up pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeMicro-Pituitary Rongeur
Overall Length6 3/4″
Working End / Blade / Jaw2 mm
ConfigurationUpward-biting
Primary FunctionBone and Soft Tissue Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical / Pituitary Surgery

The 6 3/4″ Micro-Pituitary Rongeur 2mm Panther Up combines a 6 3/4-inch overall length with a 2 mm tip size and upward-biting configuration.
Its defined working profile is intended for delicate bone and soft tissue removal in neurosurgical applications.

Design & Function

The Micro-Pituitary Rongeur features an upward-biting working configuration designed to provide a specialized orientation during delicate procedures. The tip design can assist in positioning the working end according to the requirements of the operative field.

The 2 mm tip size provides a defined cutting profile, while the 6 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a specialized rongeur.

Surgical Applications

The 6 3/4″ Micro-Pituitary Rongeur 2mm Panther Up may be used for neurosurgical and pituitary surgery applications involving delicate bone and soft tissue removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Micro-Pituitary Rongeur before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Micro-Pituitary Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Micro-Pituitary Rongeur?
The overall length is 6 3/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features 2 mm tip size.

3. Is this Micro-Pituitary Rongeur curved or straight?
It features an upward-biting configuration.

4. What is a Micro-Pituitary Rongeur used for?
It is designed for controlled bone and soft tissue removal in neurosurgical applications.

5. What clinical advantage does the upward-biting design provide?
The upward-biting design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and pituitary surgery applications where a specialized rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Micro-Pituitary Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.