6 5/16″ Foot Plate Hook .7mm tip angled down
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-43620
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-43620AISI 420 Martensitic

6 5/16″ Foot Plate Hook 0.7mm Downward Angled

4.9 / 5.0•18 Verified OR Evaluations
$100.00$117.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $17.00 (15% OFF)
  • 6 5/16″ Foot Plate Hook designed with a downward angled configuration for controlled lifting and manipulation.
  • 0.7 mm tip size provides a defined lifting profile for ENT procedures.
  • Downward angled design supports a specialized working orientation within the operative field.
  • Suitable for ENT and middle-ear surgery applications requiring a specialized instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 5/16″ Foot Plate Hook is a specialized ENT instrument designed for controlled lifting, elevation, and manipulation of the stapes footplate during middle-ear surgery. Its 0.7mm downward-angled tip provides a distinct working orientation that can assist with positioning the tip within the operative field.

With an overall length of 6 5/16 inches and a 0.7mm tip size, this Foot Plate Hook provides a defined lifting profile for ENT applications. The angled design allows the working end to approach the medial and recessed areas of the ear, supporting controlled manual manipulation during procedures.

Key Features

  • 6 5/16-inch overall length for controlled manual handling.
  • 0.7 mm tip size provides a defined lifting profile.
  • Downward angled configuration for specialized working orientation.
  • Designed for controlled lifting and manipulation of the stapes footplate.
  • Suitable for ENT and middle-ear surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Foot Plate Hook pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeFoot Plate Hook
Overall Length6 5/16″
Working End / Blade / Jaw0.7 mm tip
ConfigurationDownward Angled
Primary FunctionLifting and Manipulation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Middle-Ear Surgery

The 6 5/16″ Foot Plate Hook combines a 6 5/16-inch overall length with a 0.7 mm tip size and downward angled configuration.
Its defined working profile is intended for controlled lifting and manipulation in ENT applications.

Design & Function

The Foot Plate Hook features a downward angled working configuration designed to provide a specialized orientation during middle-ear surgery. The angled tip can assist in positioning the working end according to the requirements of the operative field.

The 0.7 mm tip provides a defined lifting profile, while the 6 5/16-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a specialized instrument.

Surgical Applications

The 6 5/16″ Foot Plate Hook may be used for ENT and middle-ear surgery applications involving controlled lifting and manipulation of the stapes footplate. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Foot Plate Hook before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Foot Plate Hook appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Foot Plate Hook?
The overall length is 6 5/16 inches.

2. What is the working end / blade or tip design of the instrument?
It features 0.7 mm tip.

3. Is this Foot Plate Hook curved or straight?
It features a downward angled configuration.

4. What is a Foot Plate Hook used for?
It is designed for controlled lifting and manipulation in ENT applications.

5. What clinical advantage does the downward angle provide?
The downward angle provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and middle-ear surgery applications where a downward angled Foot Plate Hook is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Foot Plate Hook be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.