
7″ Microvascular Spring Handle Scissors 45° Angled
Direct Manufacturer Pricing • Tax Exclusive
- 7″ Microvascular Spring Handle Scissors 45° Angled designed with an angled configuration for controlled cutting and manipulation.
- 45° angled tip provides a defined cutting profile for cardiovascular procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and delicate tissue surgery applications requiring an angled microvascular scissors.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7″ Microvascular Spring Handle Scissors 45° Angled is a specialized cardiovascular instrument designed for controlled cutting and precise manipulation in procedures involving delicate anatomical structures. Its 45-degree angled configuration provides a moderate offset between the handle and cutting blades, allowing the operator to approach the working area from an angled direction while maintaining a practical hand position.
With an overall length of 7 inches and a 45° angled tip, these scissors provide a defined cutting profile for cardiovascular applications. The spring handle design allows for controlled blade actuation through finger pressure, supporting efficient and precise cutting during surgical procedures.
Key Features
- 7-inch overall length for controlled manual handling.
- 45° angled tip provides a defined cutting profile.
- Spring handle configuration for specialized working orientation.
- Designed for controlled cutting and manipulation.
- Suitable for cardiovascular and delicate tissue surgery applications.
- Supports positioning of the cutting blades within the operative field.
- Specialized microvascular design for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Microvascular Scissors |
| Overall Length | 7″ |
| Working End / Blade / Jaw | 45° angled tip |
| Configuration | Angled |
| Primary Function | Controlled Cutting and Manipulation |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Delicate Tissue Surgery |
The 7″ Microvascular Spring Handle Scissors 45° Angled combines a 7-inch overall length with a 45° angled tip and spring handle configuration.
Its defined cutting profile is intended for controlled cutting and manipulation in cardiovascular applications.
Design & Function
The Microvascular Scissors feature a spring handle configuration designed to provide a specialized orientation during delicate tissue procedures. The angled design can assist in positioning the cutting blades according to the requirements of the operative field.
The 45° angled tip provides a defined cutting profile, while the 7-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled instrument type.
Surgical Applications
The 7″ Microvascular Spring Handle Scissors 45° Angled may be used for cardiovascular and delicate tissue surgery applications involving controlled cutting and manipulation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the microvascular scissors before use, paying particular attention to the cutting edges and handle alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the microvascular scissors appropriately to protect their cutting edges and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Microvascular Scissors?
The overall length is 7 inches.
2. What is the working end / blade or tip design of the instrument?
It features 45° angled tip.
3. Is this Microvascular Scissors curved or straight?
It features a angled configuration.
4. What is a Microvascular Scissors used for?
It is designed for controlled cutting and manipulation in cardiovascular applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the cutting blades within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and delicate tissue applications where an angled microvascular scissors is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Microvascular Scissors be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
