7″ Tissue Forceps Standard Pattern 1×2 Teeth
Direct Manufacturer Pricing • Tax Exclusive
- 7″ Tissue Forceps designed with a standard configuration for reliable tissue grasping.
- 1×2 teeth provides a defined grasping profile for neurosurgical procedures.
- Standard design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and general surgical applications requiring a standard pattern forceps.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7″ Tissue Forceps is a specialized neurosurgical instrument designed for reliable grasping of skin and soft tissue during surgical procedures. Its 1×2 toothed tips provide a distinct working orientation that can assist with positioning the grasping end within the operative field.
With an overall length of 7 inches and a 1×2 teeth configuration, this forceps provides a defined grasping profile for neurosurgical applications. The standard pattern design allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 7-inch overall length for controlled manual handling.
- 1×2 teeth configuration provides a defined grasping profile.
- Standard pattern design for versatile working orientation.
- Designed for reliable tissue grasping and manipulation.
- Suitable for neurosurgical and general surgical applications.
- Supports positioning of the working end within the operative field.
- Precision-aligned tips for consistent performance.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Tissue Forceps |
| Overall Length | 7″ |
| Working End / Blade / Jaw | 1×2 Teeth |
| Configuration | Standard |
| Primary Function | Tissue Grasping |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 7″ Tissue Forceps combines a 7-inch overall length with a 1×2 teeth configuration. Its defined working profile is intended for reliable tissue grasping in neurosurgical applications.
Design & Function
The Tissue Forceps features a standard working configuration designed to provide a specialized orientation during tissue manipulation. The 1×2 teeth design can assist in positioning the grasping end according to the requirements of the operative field.
The 1×2 teeth provide a defined grasping profile, while the 7-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a standard pattern forceps.
Surgical Applications
The 7″ Tissue Forceps may be used for neurosurgical and general surgical applications involving reliable tissue grasping. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the tissue forceps before use, paying particular attention to the working end, jaw alignment, and gripping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the tissue forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Tissue Forceps?
The overall length is 7 inches.
2. What is the working end / blade or tip design of the instrument?
It features 1×2 teeth.
3. Is this Tissue Forceps curved or straight?
It features a standard configuration.
4. What is a Tissue Forceps used for?
It is designed for controlled tissue grasping in neurosurgical applications.
5. What clinical advantage does the standard design provide?
The standard design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgical surgery?
It may be used in neurosurgical and general surgical applications where a standard pattern forceps is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Tissue Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.