7 1/2″ Debakey Vascular Dilator – 3.0mm tip
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-34221
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-34221AISI 420 Martensitic

7 1/2″ Debakey Vascular Dilator 3.0mm Tip

4.9 / 5.0•18 Verified OR Evaluations
$110.00$136.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $26.00 (19% OFF)
  • 7 1/2″ Debakey Vascular Dilator 3.0mm Tip designed with a smooth tapered configuration for controlled vessel dilation.
  • 3.0 mm tip size provides a defined dilation profile for cardiovascular procedures.
  • Smooth tapered design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and peripheral surgery applications requiring a smooth tapered dilator.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7 1/2″ Debakey Vascular Dilator 3.0mm Tip is a specialized cardiovascular instrument designed for controlled, atraumatic dilation of medium vessels in cardiovascular and peripheral procedures. Its smooth, tapered design minimizes tissue trauma, while the ergonomic handle allows precise manipulation and comfort.

With an overall length of 7 1/2 inches and a 3.0 mm tip size, this dilator provides a defined dilation profile for vascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 7 1/2-inch overall length for controlled manual handling.
  • 3.0 mm tip size provides a defined dilation profile.
  • Smooth tapered configuration for specialized working orientation.
  • Designed for controlled vessel dilation.
  • Suitable for cardiovascular and peripheral surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Debakey pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeDebakey Vascular Dilator
Overall Length7 1/2″
Working End / Blade / Jaw3.0 mm tip
ConfigurationSmooth Tapered
Primary FunctionVessel Dilation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Peripheral Surgery

The 7 1/2″ Debakey Vascular Dilator 3.0mm Tip combines a 7 1/2-inch overall length with a 3.0 mm tip size and smooth tapered configuration.
Its defined working profile is intended for controlled vessel dilation in cardiovascular applications.

Design & Function

The Debakey Vascular Dilator features a smooth tapered working configuration designed to provide a specialized orientation during vascular procedures. The tip design can assist in positioning the working end according to the requirements of the operative field.

The 3.0 mm tip provides a defined dilation profile, while the 7 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a smooth tapered instrument type.

Surgical Applications

The 7 1/2″ Debakey Vascular Dilator 3.0mm Tip may be used for cardiovascular and peripheral surgery applications involving controlled vessel dilation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Debakey Vascular Dilator before use, paying particular attention to the working end, tip alignment, and smoothness. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Vascular Dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Debakey Vascular Dilator?
The overall length is 7 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features 3.0 mm tip size.

3. Is this Debakey Vascular Dilator curved or straight?
It features a Smooth Tapered configuration.

4. What is a Debakey Vascular Dilator used for?
It is designed for controlled vessel dilation in cardiovascular applications.

5. What clinical advantage does the smooth tapered design provide?
The smooth tapered design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and peripheral surgery applications where a smooth tapered dilator is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Debakey Vascular Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.