
7 1/2″ Debakey Vascular Dilator Set of 12
Direct Manufacturer Pricing • Tax Exclusive
- 7 1/2″ Debakey Vascular Dilator Set of 12 designed with a smooth tapered configuration for atraumatic vessel dilation.
- Varied sizes with smooth tapered profiles provide a defined dilation profile for cardiovascular procedures.
- Smooth tapered design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring a smooth tapered dilator.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 1/2″ Debakey Vascular Dilator Set of 12 is a specialized cardiovascular instrument designed for precise, atraumatic dilation of vessels in cardiovascular, peripheral, and reconstructive vascular procedures. Its smooth, tapered profile provides a distinct working orientation that can assist with gradual vessel expansion while minimizing trauma to delicate vascular tissue.
With an overall length of 7 1/2 inches and a comprehensive range of sizes, this dilator set provides defined dilation profiles for cardiovascular applications. The extended length allows for excellent reach and stability in deeper operative fields, while ergonomically designed handles deliver superior tactile feedback during procedures.
Key Features
- 7 1/2-inch overall length for enhanced reach and stability.
- Comprehensive range of sizes provides defined dilation profiles.
- Smooth tapered profile for atraumatic vessel dilation.
- Designed for precise vascular dilation and expansion.
- Suitable for cardiovascular, peripheral, and reconstructive vascular applications.
- Supports positioning of the dilator within the operative field.
- Specialized Debakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Debakey Vascular Dilator |
| Overall Length | 7 1/2″ |
| Working End / Blade / Jaw | Varied sizes with smooth tapered profiles |
| Configuration | Smooth Tapered |
| Primary Function | Atraumatic Vessel Dilation |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 7 1/2″ Debakey Vascular Dilator Set of 12 combines a 7 1/2-inch overall length with a comprehensive range of sizes and smooth tapered profiles.
Its defined working profile is intended for atraumatic vessel dilation in cardiovascular applications.
Design & Function
The Debakey Vascular Dilator features a smooth tapered working configuration designed to provide a specialized orientation during vascular dilation. The tapered design can assist in positioning the dilator according to the requirements of the operative field.
The varied sizes with smooth tapered profiles provide a defined dilation profile, while the 7 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a dilator.
Surgical Applications
The 7 1/2″ Debakey Vascular Dilator Set of 12 may be used for cardiovascular and vascular surgery applications involving atraumatic vessel dilation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Debakey Vascular Dilator before use, paying particular attention to the working end and taper alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Vascular Dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Debakey Vascular Dilator?
The overall length is 7 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features varied sizes with smooth tapered profiles.
3. Is this Debakey Vascular Dilator curved or straight?
It features a smooth tapered configuration.
4. What is a Debakey Vascular Dilator used for?
It is designed for controlled atraumatic vessel dilation in cardiovascular applications.
5. What clinical advantage does the tapered design provide?
The tapered design provides a specialized working orientation for positioning the dilator within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a smooth tapered dilator is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Debakey Vascular Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
