7 1/4″ Cooley Occlusion Clamp – 3.6cm long
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-33701
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-33701AISI 420 Martensitic

7 1/4″ Cooley Occlusion Clamp 3.6cm Long

4.9 / 5.0•18 Verified OR Evaluations
$326.00$356.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $30.00 (8% OFF)
  • 7 1/4″ Cooley Occlusion Clamp designed with a straight configuration for effective vessel occlusion.
  • 3.6 cm jaw length provides a defined clamping profile for cardiovascular procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a straight occlusion clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7 1/4″ Cooley Occlusion Clamp is a specialized cardiovascular instrument designed for effective and atraumatic vessel occlusion during cardiovascular and vascular procedures. Its 3.6 cm jaw length provides optimal coverage for secure vessel control, while the atraumatic design minimizes tissue damage.

With an overall length of 7 1/4 inches and a 3.6 cm jaw length, this occlusion clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach the vessel from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 7 1/4-inch overall length for controlled manual handling.
  • 3.6 cm jaw length provides a defined clamping profile.
  • Straight configuration for specialized working orientation.
  • Designed for effective vessel occlusion.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Occlusion Clamp
Overall Length7 1/4″
Working End / Blade / Jaw3.6 cm
ConfigurationStraight
Primary FunctionVessel Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 7 1/4″ Cooley Occlusion Clamp combines a 7 1/4-inch overall length with a 3.6 cm jaw length and straight configuration.
Its defined working profile is intended for effective vessel occlusion in cardiovascular applications.

Design & Function

The Cooley Occlusion Clamp features a straight working configuration designed to provide a specialized orientation during vessel occlusion. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 3.6 cm jaw length provides a defined clamping profile, while the 7 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a straight occlusion clamp.

Surgical Applications

The 7 1/4″ Cooley Occlusion Clamp may be used for cardiovascular and vascular surgery applications involving vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the occlusion clamp before use, paying particular attention to the jaw alignment and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the occlusion clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Occlusion Clamp?
The overall length is 7 1/4 inches.

2. What is the working end / jaw design of the instrument?
It features 3.6 cm jaw length.

3. Is this Occlusion Clamp curved or straight?
It features a Straight configuration.

4. What is a Cooley Occlusion Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.

5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a straight occlusion clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Occlusion Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.