7 1/4″ FineTouch Ryder Needle Holder
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-56567
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OrthopedicSKU: SP-56567AISI 420 Martensitic

7 1/4″ Ryder Needle Holder FineTouch

4.9 / 5.0•18 Verified OR Evaluations
$200.00$250.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $50.00 (20% OFF)
  • 7 1/4″ Ryder Needle Holder FineTouch designed with an ergonomic configuration for precise needle control and suturing.
  • FineTouch precision jaws provide a defined grasping profile for orthopedic procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for orthopedic and reconstructive surgery applications requiring a precise needle holder.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7 1/4″ Ryder Needle Holder FineTouch is a specialized orthopedic instrument designed for precise needle control during suturing procedures. Its fine precision jaws provide a distinct working orientation that can assist with positioning the needle within the operative field.

With an overall length of 7 1/4 inches and a secure needle grip, this needle holder provides a defined grasping profile for orthopedic applications. The ergonomic design allows the working end to approach the tissue from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 7 1/4-inch overall length for controlled manual handling.
  • FineTouch precision jaws provide a defined grasping profile.
  • Ryder-style handle design for specialized working orientation.
  • Designed for precise needle control during suturing.
  • Suitable for orthopedic and reconstructive surgery applications.
  • Supports positioning of the needle within the operative field.
  • Specialized Ryder pattern for professional orthopedic instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeRyder Needle Holder
Overall Length7 1/4″
Working End / Blade / JawFineTouch precision jaws
ConfigurationErgonomic
Primary FunctionNeedle Control and Suturing
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOrthopedic / Reconstructive Surgery

The 7 1/4″ Ryder Needle Holder FineTouch combines a 7 1/4-inch overall length with FineTouch precision jaws and ergonomic design.
Its defined working profile is intended for precise needle control during suturing in orthopedic applications.

Design & Function

The Ryder Needle Holder features an ergonomic design designed to provide a specialized orientation during suturing procedures. The precision jaws can assist in positioning the needle according to the requirements of the operative field.

The FineTouch precision jaws provide a defined grasping profile, while the 7 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for orthopedic procedures requiring a needle holder.

Surgical Applications

The 7 1/4″ Ryder Needle Holder FineTouch may be used for orthopedic and reconstructive surgery applications involving precise needle control and suturing. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the needle holder before use, paying particular attention to the working end, jaw alignment, and gripping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the needle holder appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Needle Holder?
The overall length is 7 1/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features FineTouch precision jaws.

3. Is this Needle Holder curved or straight?
It features an ergonomic configuration.

4. What is a Needle Holder used for?
It is designed for controlled needle control and suturing in orthopedic applications.

5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the needle within the operative field.

6. Is this instrument suitable for orthopedic surgery?
It may be used in orthopedic and reconstructive surgery applications where a precise needle holder is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Needle Holder be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.