7 1/4″ Watson-Cheyne Probe and Dissector Double-Ended
Direct Manufacturer Pricing • Tax Exclusive
- 7 1/4″ Watson-Cheyne Probe and Dissector Double-Ended designed with a double-ended configuration for probing and dissecting delicate tissues.
- Double-ended tips provide a defined probing and dissecting profile for neurosurgical procedures.
- Ergonomic design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and microsurgical applications requiring a double-ended instrument.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 1/4″ Watson-Cheyne Probe and Dissector Double-Ended is a specialized neurosurgical instrument designed for probing, dissecting, and manipulating delicate tissues. Its double-ended design provides two functional tips that can assist with varied surgical applications, while the 7 1/4″ length allows access to deep or confined anatomical spaces.
With an overall length of 7 1/4 inches, this probe and dissector provides a defined working profile for neurosurgical applications. The ergonomic design allows the working end to approach delicate tissues from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 7 1/4-inch overall length for controlled manual handling.
- Double-ended design provides two functional tips for versatile applications.
- Ergonomic configuration for specialized working orientation.
- Designed for probing, dissecting, and manipulating delicate tissues.
- Suitable for neurosurgical applications.
- Supports positioning of the working ends within the operative field.
- Specialized Watson-Cheyne pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Watson-Cheyne Probe and Dissector |
| Overall Length | 7 1/4″ |
| Working End / Blade / Jaw | Double-ended tips |
| Configuration | Double-ended |
| Primary Function | Probing and Dissecting |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 7 1/4″ Watson-Cheyne Probe and Dissector Double-Ended combines a 7 1/4-inch overall length with double-ended tips.
Its defined working profile is intended for probing and dissecting in neurosurgical applications.
Design & Function
The Watson-Cheyne Probe and Dissector features a double-ended working configuration designed to provide a specialized orientation during neurosurgical procedures. The double-ended design can assist in positioning the working ends according to the requirements of the operative field.
The double-ended tips provide a defined probing and dissecting profile, while the 7 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a double-ended instrument.
Surgical Applications
The 7 1/4″ Watson-Cheyne Probe and Dissector Double-Ended may be used for neurosurgical and microsurgical applications involving probing and dissecting delicate tissues. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Watson-Cheyne Probe and Dissector before use, paying particular attention to the working ends and tips. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Watson-Cheyne Probe and Dissector appropriately to protect its working ends and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Probe and Dissector?
The overall length is 7 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features double-ended tips.
3. Is this Probe and Dissector curved or straight?
It features a double-ended configuration.
4. What is a Probe and Dissector used for?
It is designed for controlled probing and dissecting in neurosurgical applications.
5. What clinical advantage does the double-ended design provide?
The double-ended design provides a specialized working orientation for positioning the working ends within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and microsurgical applications where a double-ended Probe and Dissector is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Probe and Dissector be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.