7 1/4″ Pituitary Rongeur Graduated 2mm Jaw Panther Down
Direct Manufacturer Pricing • Tax Exclusive
- 7 1/4″ Pituitary Rongeur Graduated 2mm Jaw Panther Down designed with a downbiting configuration for controlled tissue and disc excision.
- 2 mm jaw dimension provides a defined grasping profile for neurosurgical procedures.
- Downbiting design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and spinal surgery applications requiring a downbiting rongeur.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 7 1/4″ Pituitary Rongeur Graduated 2mm Jaw Panther Down is a specialized neurosurgical instrument designed for controlled tissue and disc excision in spinal procedures. Its downbiting 2mm jaws allow access to targeted areas while minimizing trauma to surrounding structures.
With an overall length of 7 1/4 inches and a 2 mm jaw dimension, this rongeur provides a defined grasping profile for neurosurgical applications. The graduated markings assist in accurate depth control during delicate procedures, ensuring precision and safety in the operative field.
Key Features
- 7 1/4-inch overall length for controlled manual handling.
- 2 mm jaw dimension provides a defined grasping profile.
- Downbiting configuration for specialized working orientation.
- Designed for controlled tissue and disc excision.
- Suitable for neurosurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Panther pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Pituitary Rongeur |
| Overall Length | 7 1/4″ |
| Working End / Blade / Jaw | 2 mm |
| Configuration | Downbiting |
| Primary Function | Tissue and Disc Excision |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 7 1/4″ Pituitary Rongeur Graduated 2mm Jaw Panther Down combines a 7 1/4-inch overall length with a 2 mm jaw dimension and downbiting configuration.
Its defined working profile is intended for controlled tissue and disc excision in neurosurgical applications.
Design & Function
The Pituitary Rongeur features a downbiting working configuration designed to provide a specialized orientation during spinal procedures. The 2 mm jaw design can assist in positioning the working end according to the requirements of the operative field.
The 2 mm jaw profile provides a defined grasping profile, while the 7 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a downbiting instrument.
Surgical Applications
The 7 1/4″ Pituitary Rongeur Graduated 2mm Jaw Panther Down may be used for neurosurgical and spinal surgery applications involving tissue and disc excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Pituitary Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Pituitary Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Pituitary Rongeur?
The overall length is 7 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 2 mm jaw dimension.
3. Is this Pituitary Rongeur curved or straight?
It features a downbiting configuration.
4. What is a Pituitary Rongeur used for?
It is designed for controlled tissue and disc excision in neurosurgical applications.
5. What clinical advantage does the downbiting design provide?
The downbiting design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgical surgery?
It may be used in neurosurgical and spinal surgery applications where a downbiting Pituitary Rongeur is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Pituitary Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.