7″ Cooley Peripheral Vascular Clamp 45° Jaws
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-38259
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
cardio vescular instrumentSKU: SP-38259AISI 420 Martensitic

7″ Cooley Peripheral Vascular Clamp 45° Jaws

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)

The 7″ Cooley Peripheral Vascular Clamp with 45° Jaws is designed for controlled clamping of blood vessels during vascular and cardiovascular procedures. Its angled jaw configuration supports access to selected anatomical structures and helps surgeons position the instrument according to procedural requirements.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7″ Cooley Peripheral Vascular Clamp, 45° Jaws is a specialized surgical instrument designed for temporary vascular occlusion during selected vascular and cardiovascular procedures. Its 7-inch overall length provides a practical working size for handling in the operative field, while the 45-degree jaw angle helps facilitate access to vessels where an angled approach is preferred. This configuration makes the instrument a useful option for professional surgical instrument collections requiring specialized vascular clamps.

Design and Jaw Configuration

The defining feature of this Cooley peripheral vascular clamp is its 45-degree angled jaws. This design allows the surgeon to approach selected blood vessels from an angled direction rather than relying on a straight jaw configuration. Depending on the operative site and surrounding anatomy, angled jaws may help improve positioning and maneuverability during vessel clamping.

The 7-inch length offers a balance between instrument reach and handling control. Proper jaw alignment and appropriate placement are important for achieving the intended clamping function. The exact jaw profile, serration pattern, clamping pressure, and locking mechanism should be verified against the manufacturer's specifications for the supplied model.

Surgical Applications

Cooley peripheral vascular clamps are used in vascular surgical settings where controlled vessel clamping is required. Depending on the specific model and its intended application, this instrument may be considered for selected peripheral vascular procedures, vessel isolation, and temporary interruption of blood flow during surgical manipulation.

Its angled jaw design can be useful when approaching vessels from a direction that is difficult to reach with a straight clamp. Instrument selection should account for vessel diameter, tissue characteristics, anatomical access, and the requirements of the planned procedure. The clamp must be used by qualified surgical professionals according to established clinical protocols and the manufacturer's instructions.

Construction and Material

Professional vascular clamps are commonly manufactured from medical-grade stainless steel, which offers strength, corrosion resistance, and compatibility with appropriate instrument reprocessing procedures. However, the exact material grade, surface finish, and construction details of this particular Cooley clamp should be confirmed with the supplier.

A properly maintained vascular clamp should have aligned jaws, a functional locking mechanism where applicable, and smooth surfaces without visible defects. These characteristics support appropriate handling and help maintain the instrument's intended performance throughout its service life.

Benefits in Vascular Instrumentation

The 7″ Cooley Peripheral Vascular Clamp provides a specialized option for surgical teams requiring an angled vascular clamping instrument. Its 45-degree jaws offer an alternative to straight and differently angled clamps, allowing selection according to the surgical approach and anatomical requirements.

The instrument's compact overall length can support handling in selected operative fields, while its dedicated vascular design makes it relevant to specialized cardiovascular and peripheral vascular instrument sets. Choosing an appropriately sized clamp helps surgical professionals work with greater control and avoid using instruments that are unsuitable for the vessel or procedure.

Cleaning, Sterilization, and Maintenance

Reusable surgical clamps must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions. Remove visible soil promptly using an approved cleaning procedure, paying attention to the jaws, joints, and locking components. Rinse, dry, inspect, and package the instrument as directed before sterilization.

Inspect the jaw alignment, locking function, and surface condition before each use. Remove the instrument from service if it shows corrosion, cracks, deformation, loose components, or impaired function. Use only validated reprocessing methods compatible with the instrument's materials and construction.

The 7″ Cooley Peripheral Vascular Clamp with 45° Jaws is a specialized option for professional surgical environments requiring controlled vessel clamping and an angled approach. Confirm the manufacturer's specifications to ensure the instrument meets the needs of the intended application.

Key Features

  • Instrument Type: Cooley peripheral vascular clamp

  • Overall Length: 7 inches

  • Jaw Angle: 45 degrees

  • Primary Function: Controlled vascular clamping

  • Surgical Specialty: Peripheral vascular and cardiovascular surgery

  • Angled Jaw Design: Supports access from an angled approach

  • Instrument Handling: Designed for positioning by qualified surgical professionals

  • Construction Material: Confirm with the manufacturer or supplier

  • Reprocessing: Follow validated cleaning and sterilization instructions

  • Maintenance: Inspect jaw alignment, locking function, and surface condition regularly

Product Specifications Table

SpecificationDetails
Product NameCooley Peripheral Vascular Clamp
Instrument CategoryVascular Surgical Clamp
Overall Length7 inches
Jaw ConfigurationAngled
Jaw Angle45°
Primary FunctionVascular clamping
Surgical SpecialtyPeripheral Vascular and Cardiovascular Surgery
MaterialTo be confirmed by manufacturer
Reusable StatusConfirm with manufacturer
Sterilization MethodAccording to validated manufacturer instructions

Frequently Asked Questions

1. What is a 7″ Cooley Peripheral Vascular Clamp used for?

It is designed for controlled clamping of blood vessels during selected peripheral vascular and cardiovascular surgical procedures.

2. What is the purpose of the 45-degree jaws?

The 45-degree jaw angle helps provide an angled approach to selected vessels, which may improve instrument positioning in certain operative fields.

3. Why is the 7-inch length important?

The 7-inch overall length provides a defined working size for handling and access. Its suitability depends on the anatomical location and requirements of the procedure.

4. Is this clamp suitable for cardiovascular surgery?

It may be appropriate for selected cardiovascular and peripheral vascular procedures when its design and specifications meet the clinical requirements.

5. What material is used to manufacture a Cooley vascular clamp?

Medical-grade stainless steel is commonly used for reusable surgical clamps. The exact material grade of this product should be confirmed with the manufacturer.

6. How should a Cooley Peripheral Vascular Clamp be sterilized?

Follow the manufacturer's validated instructions for cleaning, inspection, packaging, and sterilization. The appropriate method depends on the instrument's verified construction and compatibility.

7. How do I choose between straight and angled vascular clamps?

Selection depends on the vessel's location, anatomical access, required jaw orientation, and the surgeon's preferred technique. The instrument must also meet the requirements of the intended procedure.